Study on Measuring Device for Bearing Clearance of Hemisphere Dynamic Pressure Motor

2018-02-20 03:39:34YANXiaojunYUDetaoTANGZhaofang
Aerospace China 2018年1期

YAN Xiaojun, YU Detao, TANG Zhaofang

Beijing Institute of Aerospace Control Devices, Beijing 100039

Abstract: The clearance of the hemisphere dynamic pressure motor is small and difficult to measure, the measurement method of micro clearance is studied. The shortcomings of the original measurement method are analyzed, and a clearance measuring device for the hemisphere dynamic pressure motor is designed, which improves the measurement efficiency and stability.

Key words: hemisphere dynamic pressure motor, measurement of micro clearance, precision measurement, research on device

1 INTRODUCTION

The gyro motor, as the core component of gyro instrument, provides a stable and reliable moment of inertia for gyro instruments. Its performance directly affects the accuracy and reliability of instruments, platforms, even missiles and spacecraft.Implimentation of the supporting methods for gyro motor can be divided into two: ball bearing support and dynamic air pressure bearing support. The dynamic air bearing motor is referred to as a dynamic pressure motor, has the advantages of small volume, low vibration noise, high speed, high reliability, low friction loss, long life and other advantages. It is widely used in all kinds of high precision and high reliability gyroscope instruments, and is also used in aviation, aerospace, marine and in other important instruments[1].

The dynamic air pressure bearing used in a dynamic air bearing motor can be defined as two precision machined surfaces separated by an air film. It takes advantage of the viscosity and stiffness of the air, with the dry compressed air introduced into the air bearing clearance through some blowholes on the surface of the bearing. The clearance of the air bearing is maintained with compressed air, with the air film bearing the pressure load and achieves stable action[2].

With the motor axis as the reference, the air bearing has axial and radial clearance, with its bearing clearance of only 0.003- 0.008 mm, as shown in Figure 1. Therefore, the accurate measurement of the axial and radial clearance of the bearing is the key process in the machining and assembling process of the dynamic pressure motor[3].

Figure 1 Model of dynamic pressure motor

At present, the measurement of the bearing clearance of the hemisphere dynamic pressure motor depends entirely on the way that the operator manually suspends the weights, as shown in Figure 2. The motor needs to be clamped two times in the axial and radial measurement process, measuring operation efficiency is low, and the reliability is not optimum. It was essential to study a high efficiency measurement method for the motor clearance.

Figure 2 Manual method of clearance measurement

2 RESEARCH ON A HIGH EFFICIENCY MEASUREMENT METHOD FOR BEARING CLEARANCE FOR THE HEMISPHERE DYNAMIC PRESSURE MOTOR

The bearing clearance of the hemisphere dynamic pressure motor is very small. A set of devices which can accurately and efficiently measure the axial and radial clearance was urgently needed to solve the complicated and inefficient measurement methods.

2.1 Selection of Measuring Sensors

A displacement sensor is the key component for the motor clearance measurement device. Its precision and other performance indexes have the greatest impact on the accuracy of the whole system. Therefore, it is a prerequisite and key to ensure the precision of the system to select a high-precision displacement sensor which is suitable for the performance and to meet the requirements of the measurement[4]. The measurement of bearing clearance for the dynamic motor requires that the resolution of displacement sensor is 0.1 μm. The motor rotor is not rotated when measuring, so a contact or non-contact sensor can be used. In order to meet the requirements for the clearance measurement, the displacement sensor should have the characteristics of high precision, high sensitivity and have a high frequency response.

The two kinds of sensors in accordance with the above requirements are the inductance micrometer (contact type) and capacitance micrometer (non-contact type). The capacitance micrometer is subject to the edge effect, electromagnetic interference and other environmental factors. Hence there are several problems in the application of capacitance sensors for the measurement of motor clearance. First of all, the capacitance sensor is more sensitive. If the installation position is not accurate or subjected to external vibration and other disturbances,it will be prone to larger errors. Another problem is that when measuring the radial clearance of a smaller motor, the measured surface is small or the curvature is large, which will lead to the enhancement of the edge effect of the capacitance sensor and seriously affect the measurement result and make the measurement result inaccurate[5]. In view of the above analysis, the inductor micrometer is the preferred solution.

2.2 Introduction of the Measuring Principle of the Clearance Measuring Device

The device uses contact measurement and contact loading to measure the clearance of the motor, as shown in Figure 3.An inductor micrometer is arranged at both ends of the motor shaft in radial and axial directions, and a contact loading device is arranged on the opposite side of each inductor micrometer.Each of the inductance micrometers and the loading device is equipped with a trimming device for adjusting the distance between the part and the motor shaft.

Take the axial clearance measurement as an example, as shown in Figure 3. First, the axial loading devices are placed under the motor; the loading device is not working at this time.The inductor micrometer on the opposite side is adjusted to contact the motor shaft, and the position value A1 in the selfweight state is measured. Next, the loading device is operated,and as the spring compresses, the load force reaches its pre-determined value, and the inductance micrometer measures the position value A2in the loaded state. The data acquisition card collects the test data and calculates the axial clearance for ΔA=A2-A1. The radial clearance measurement approach is the same as the axial measurement principle, and the detailed measurement process is shown in Figure 4.

Figure 3 Schematic diagram of clearance measuring device

Figure 4 Clearance measurement working process

3 COMPONENT AND FUNCTION MODULE OF MOTOR CLEARANCE MEASUREMENT DEVICE

The dynamic pressure motor clearance measuring device consists of three main modules, including the attitude control module, the contact loading module and the contact measurement module. By means of attitude switching, the motor can be installed at one time, and the clearance value in the two directions can be measured efficiently and accurately.

3.1 Attitude Control Module

The device adopts as witching attitude to measure the clearance, and the motor is installed once for the measurement.The sensor and the dynamic pressure motor are all fixed on a bracket, and can rotate around 360 degrees under the action of a dividing head. The axis of the sensor is perpendicular to the motor axis, and the relative position is fixed. By rotating the motor by 90 degrees, efficient switching between axial and radial direction can be realized, as shown in Figure 5 and Figure 6.

3.2 Contact-type Loading Module

Three of the contact loading modules are arranged in the radial and axial directions, and the structure diagram is shown in Figure 7. By turning the adjusting nut (7), the slider (4) moves forward until the push rod (8) contacts the motor shaft. By continuing to rotate the adjusting nut (7) compression of the spring occurs. Once the pressure sensor (5) shows that the pressure value is up to its preset value, the adjusting nut (7) rotation is stopped, and the quantitative loading of the motor is completed.

Figure 5 Radial clearance measurement

Figure 6 Axial clearance measurement

Figure 7 Schematic diagram of contact-type loading module

3.3 Contact-type Measurement Module

According to the analysis of the measuring sensors above,the device uses inductance micrometers to measure the clearance of the motor. Each inductance micrometer is equipped with a fine-tuning device to adjust the working distance between the head and the motor. The measurement module is arranged on the opposite side of the loading module, the structure is shown as shown in Figure 8. The probe (1) is fixed to the adjustment slider (4) by a cone (2); rotation of the adjusting nut (5)realizes the position adjustment of the probe (1). After adjusting to the appropriate measurement position, the screw (3) is tightened to fix the head and the measurement can be started.

Figure 8 Schematic diagram of sensor turning device

4 ANALYSIS OF EXPERIMENTAL RESULTS OF THE MOTOR CLEARANCE MEASUREMENT DEVICE

The motor clearance measuring device uses dual way dividing head to switch the measuring attitude, avoiding the need to repeat the loading measurement process, and the loading method is simple, which greatly improves the efficiency. For the experiment, the measurement time for the motor clearance measurement device is less than 2 min, while the traditional manual measurement time is about 10 min, so the efficiency has increased by more than 5 times.

The loading and measuring methods of the clearance measuring device are stable and reliable, so the measurement data is more stable than the manual measurement. Taking the radial clearance as an example, as shown in Table 1, the motor rotates 60 degrees to measure one point, and the average value of 6 measurements is taken. The same measurement method takes 6 times. The maximum deviation is 0.025 μm, and the average value of radial clearance is 3.033 μm. The accuracy and reliability of measurement are higher than manual measurement.

Table 1 Measurement results of radial clearance of bearing

5 CONCLUSIONS

1) Through the research the efficient measurement method of the bearing clearance of the hemisphere dynamic pressure motor, the working conditions of the two displacement sensors are compared, and the contact inductance micrometer was selected as the sensor for measuring the clearance of the motor. By means of attitude switching, the motor can be installed once, and it simplifies the measurement process.

2) The function modularization of the motor clearance measurement device is realized through the design of an attitude control module, a contact loading module and a contact measurement module. The precision and efficiency of the motor clearance measurement are improved by the design of the fine-tuning device.

主站蜘蛛池模板: 不卡的在线视频免费观看| 欧美亚洲欧美区| 成人国产精品网站在线看| 日韩午夜福利在线观看| 老汉色老汉首页a亚洲| 成人av专区精品无码国产| 日韩高清一区 | 99伊人精品| 青青操视频在线| 呦视频在线一区二区三区| 国产免费久久精品99re不卡 | 久久人搡人人玩人妻精品一| 精品久久蜜桃| 国产黄网站在线观看| 理论片一区| 亚洲人成在线精品| 国产精品99在线观看| 婷婷开心中文字幕| 亚洲人成色在线观看| 欧美日韩国产在线人成app| 国产精品综合色区在线观看| 97超爽成人免费视频在线播放| 国内精品视频在线| 女人天堂av免费| 自慰高潮喷白浆在线观看| 亚洲国产日韩在线观看| 亚洲第一国产综合| a亚洲天堂| 欧美三级自拍| 久久精品亚洲专区| 国产99视频免费精品是看6| 国产精品亚洲一区二区三区z| 亚洲午夜福利在线| 九色最新网址| 青青青草国产| www.狠狠| 久久美女精品| 国产成人免费高清AⅤ| 综合网久久| 久久精品视频一| 色亚洲成人| 国产中文一区a级毛片视频| 久996视频精品免费观看| 日韩精品一区二区三区大桥未久| 中字无码av在线电影| 亚洲国产成人久久精品软件| 欧美日本在线| 亚洲成肉网| 无码高潮喷水在线观看| 欧美69视频在线| 国产熟女一级毛片| 天天综合网色中文字幕| 日韩不卡高清视频| 国产精品三级专区| 国产电话自拍伊人| 黄色福利在线| 国产熟睡乱子伦视频网站| 欧美午夜在线播放| 亚洲美女AV免费一区| 久久综合色88| 一区二区三区国产精品视频| 久久婷婷五月综合色一区二区| 高潮毛片无遮挡高清视频播放 | 午夜精品久久久久久久99热下载 | 国产在线观看一区精品| а∨天堂一区中文字幕| 亚洲天堂网2014| 好吊日免费视频| 国产三级成人| 久久综合婷婷| 欧美午夜网| 91久久偷偷做嫩草影院精品| 久久久久亚洲av成人网人人软件 | 国产亚洲现在一区二区中文| 波多野结衣一区二区三区88| 黄色网址手机国内免费在线观看| 欧美精品v欧洲精品| 性欧美在线| 一级毛片免费观看不卡视频| 911亚洲精品| 成人一区在线| 2021亚洲精品不卡a|