趙 輝,趙少華,王紅君,岳有軍
(1.天津市復(fù)雜控制理論與應(yīng)用重點(diǎn)實(shí)驗(yàn)室(天津理工大學(xué)),天津 300384;2.天津農(nóng)學(xué)院,天津 300384)
Research on State Estimation of Hybrid Power System Based on APSI Multi-stage StrategiesZHAO Hui1,2, ZHAO Shaohua1, WANG Hongjun1,YUE Youjun1
(1.Tianjin Key Laboratory for Control Theory and Application in Complicated System (Tianjin University of Technology),
Tianjin 300384, China;2.Tianjin Agricultural University, Tianjin 300384, China)
?
基于APSI多級策略下的混合電力系統(tǒng)狀態(tài)估計(jì)研究
趙輝1,2,趙少華1,王紅君1,岳有軍1
(1.天津市復(fù)雜控制理論與應(yīng)用重點(diǎn)實(shí)驗(yàn)室(天津理工大學(xué)),天津300384;2.天津農(nóng)學(xué)院,天津300384)
Research on State Estimation of Hybrid Power System Based on APSI Multi-stage StrategiesZHAO Hui1,2, ZHAO Shaohua1, WANG Hongjun1,YUE Youjun1
(1.Tianjin Key Laboratory for Control Theory and Application in Complicated System (Tianjin University of Technology),
Tianjin 300384, China;2.Tianjin Agricultural University, Tianjin 300384, China)
0引言
近年,電力系統(tǒng)狀態(tài)估計(jì)已經(jīng)成為大型電力系統(tǒng)網(wǎng)絡(luò)不可或缺的一部分。電力系統(tǒng)狀態(tài)估計(jì)作為新興智能電網(wǎng)運(yùn)行控制的一部分,應(yīng)當(dāng)與當(dāng)前電網(wǎng)的發(fā)展趨勢保持同步。這就要求所采用的策略對傳統(tǒng)的狀態(tài)估計(jì)有明顯的改善,電力系統(tǒng)狀態(tài)估計(jì)的優(yōu)劣主要體現(xiàn)在估計(jì)精度和可觀性上,因此如何提高精度和保證可觀性要求依然是狀態(tài)估計(jì)策略最為關(guān)心的問題。傳統(tǒng)的狀態(tài)估計(jì)是把所采集到的數(shù)據(jù)通過遠(yuǎn)程終端(RTU)傳送到電力系統(tǒng)調(diào)度中心,進(jìn)而對數(shù)據(jù)進(jìn)行處理和分析,得到電網(wǎng)實(shí)時(shí)運(yùn)行所的實(shí)時(shí)數(shù)據(jù)[1]。傳統(tǒng)的SCADA系統(tǒng)在傳輸數(shù)據(jù)時(shí)存在很大的噪聲誤差及干擾,并且采樣周期較長,無時(shí)間同步裝置,使得不同地點(diǎn)無法獲取同一時(shí)間的數(shù)據(jù)信息。基于全球定位系統(tǒng)的(GPS)的相量量測單元(PMU)的出現(xiàn),解決了傳統(tǒng)監(jiān)測系統(tǒng)采集數(shù)據(jù)不精確以及采集時(shí)間不同步的問題[2]。但是由于技術(shù)和價(jià)格的問題,PMU并不能完全取代SCADA量測裝置。在很長一段時(shí)間內(nèi)必是兩者共存的狀態(tài)。因此,如何構(gòu)造策略使兩者混合狀態(tài)下效率最高成為目前面臨的重要問題之一。
利用PMU 和SCADA 量測構(gòu)成的混合測量系統(tǒng),運(yùn)用直角坐標(biāo)形式等效電流量測變換技術(shù)處理節(jié)點(diǎn)注入功率量測和支路功率量測,把信息矩陣轉(zhuǎn)換成常數(shù)矩陣,再運(yùn)用奇異值分解求解量測方程[3]。……