祝海涵 宋樂 何強龍
摘 要:?;⒅楸厣皾{是建筑外墻保溫體系中應用較多的技術之一,保溫面層的空鼓則是常見的質量缺陷。據此,本文分析了?;⒅楸厣皾{產生空鼓的原因,并針對原因提出一些施工質量控制措施。實踐證明,這些措施對避免空鼓有顯著成效,促進了玻化微珠保溫砂漿的發展與應用。
關鍵詞:?;⒅?;保溫砂漿;空鼓控制;施工;節能
中圖分類號:TU761.1 文獻標識碼:A 文章編號:1003-5168(2018)20-0124-03
Study on Air Drum Control of Vitrified Microbead Insulation Mortar
ZHU Haihan SONG Le HE Qianglong
(China Construction Fourth Engineering Bureau Co., Ltd.,Nanchang Jiangxi 330000)
Abstract: Glazed hollow bead insulation mortar is one of the most widely used technologies in building external wall insulation system. Hollowing of insulation layer is a common quality defect. Accordingly, the reasons for hollow hollowing of glazed hollow bead insulation mortar were analyze, and some construction quality control measures were put forward for reasons. Practice had proved that these measures had significant effect on avoiding hollowing, and promoted the development and application of glazed hollow bead thermal insulation mortar.
Keywords: vitrified microsphere;thermal insulation mortar;hollowing control;construction;energy saving
?;⒅楸厣皾{具有極好的耐候穩定性、優異的保溫隔熱性、防火性能好、施工簡單和性價比高等特點,其應用越來越普及。玻化微珠保溫砂漿系統由界面層、保溫砂漿保溫層、抗裂砂漿纖維網、抗裂砂漿和飾面層組成,在工程中出現的空鼓是其主要的工程質量問題之一。究其原因,不僅與保溫砂漿本身材料的性能有關,更多的是與施工工藝、施工質量控制及配套材料有關。
1 工程概況
本工程主要由10棟29~33層住宅樓組成,占地面積68 313m2,建筑面積約289 571m2,地下室不同階段土方開挖深度1.8~7m,地下建筑面積約50 476m2。擬建建筑物均為框剪結構。由于現場樓棟較多,工程量大,因此,做好外墻外保溫的質量控制至關重要。圖1是俯瞰的工程樓棟圖。
2 出現空鼓的原因
2.1 材料因素
第一,材料本身配方問題。材料的配方沒有根據施
工現場的工程條件進行優化,保溫砂漿的保水性、抗拉強度等性能不能滿足工程的要求而出現空鼓。材料本身品質有問題,導致砂漿保水效果不好,形成空鼓[1]?!?br>