999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

Quantification of Carcinoembryonic Antigen by Single Particle Inductively Coupled Plasma Mass Spectrometry

2022-04-22 03:37:10HUANGZiliHUYueliLIUJingWUYiZHAOJinyiLIURuiYi
分析測試學報 2022年4期

HUANG Zi-li,HU Yue-li,LIU Jing,WU Yi,ZHAO Jin-yi,LIU Rui,LüYi,2*

(1.Key Laboratory of Green Chemistry&Technology,Ministry of Education,College of Chemistry,Sichuan University,Chengdu 610064,China;2.Analytical&Testing Center,Sichuan University,Chengdu 610064,China)

Abstract:Cancer ranks as the leading threat to life expectancy all over the world,based on the latest estimations.Timely diagnosis and treatment of malignancies are still essential procedures to control the growing burden of cancer incidence and mortality.Single particle inductively coupled plasma mass spectrometry(spICP-MS)is a detection method for single particles in time-resolved mode.Inheriting the advantages of ICP-MS,spICP-MS ensures the single-particle counting with high sensitivity and high element resolutions.For immunoassays by this mode,there are breakthroughs not only in improving the detection limits of heterogeneous immunoassay but also in achieving multiplex homogeneous immunoassays with a simpler procedure.In this work,a single particle counting strategy was achieved by spICP-MS for sensitive carcinoembryonic antigen(CEA)evaluation.Gold nanoparticles(AuNPs)with a diameter of 50 nm were synthesized by one-step sodium citrate reduction,which were further applied to CEA-specific capturing.Anti-CEA antibody labeled AuNPs were synthesized by electrostatic adsorption between disulfide bonds exposed on the anti-CEA antibodies and the surface of AuNPs.The strategy was based on sandwich immunoassay where anti-CEA antibody labeled magnetic beads(MBs)were applied to capture CEA and antibody labeled AuNPs.After separation by a magnet,MBs were enriched at the bottom of the centrifugal tube,while the remaining AuNPs in the supernatant were counted by spICP-MS.The more CEA occurred in the sample,the more AuNPs probes were captured on the surface of MBs,and the fewer numbers of detectable remaining AuNPs were found in the supernatant.The proposed method was more direct and facile without washing steps,compared with the traditional MBs strategy.The experimental conditions were optimized,including magnetic beads volume applied in immunoassay and dilution ratio of the sample in spICP-MS.Under the optimal conditions,spICP-MS could accurately determine the change of AuNPs numbers in the process of CEA immunoassay,with an efficiency of 2.1%.The proposed method provided a three-orders-of-magnitude linear range(0.05-20 ng/mL,r2=0.997)with a limit of detection(LOD)as low as 0.017 ng/mL for CEA quantification.The method was also successfully utilized in serum sample analysis with good selectivity,exhibiting a great potential in cancer diagnosis.

Key words:single particle ICP-MS;AuNPs;magnetic beads;CEA evaluation

In the past 2020,there were proximately 19.3 million new cases and 10 million deaths worldwide,making cancer a public health priority that needs efficient control[1].Early diagnosis of cancer which can give warning in time is still an efficient protocol to tackle this dilemma[2-4].Single particle ICP-MS(spICP-MS)based immunoassay,inheriting the advantages of ICP-MS where the revolution of absolute quantification has been massively achieved,is one of the state-of-the-art protocols for cancer diagnosis due to its high specificity(high resolutions among metal stable isotopes)and throughputs(noble metal and lanthanide nanoparticles can be tactfully applied)[5-8].Moreover,it is because that a gaseous ion cloud with large amounts of detectable ions can be counted per transient pulse after vaporized and ionized by ICP,spICP-MS concentrates on the numbers of particles instead of the ion itself,exhibiting potential on reaching higher sensitivity in immunoassay when applying nanoparticles counting[9-10].Gold nanoparticles(AuNPs)serve as the foremost studied nanomaterials with simple synthesis and adjustable morphology.Endowed with various properties that can be used for sensor and assay development,AuNPs have been widely adopted for multi-discipline research[11].In spICP-MS,the high abundance of+Au197(100%)guarantees a high signal response of AuNPs without other isotopic interference.In 2009,Zhang′s group firstly proposed a spICP-MS based competitive heterogeneous immunoassay for sensitive detection ofα-fetoprotein(AFP)using 45 nm AuNPs in 96-well microtiter plates[12].Later,they groundbreakingly reported an AuNPs based homogeneous DNA assay with dual data acquisition,widening the application of spICP-MS in other biological molecules[13].Having noticed the advantages of spICP-MS in evaluating signal changes within a homogeneous level,a series of homogeneous protocols,which are more facile than a heterogenous strategy based clinical practice without wash and separation procedures,have been reported for single analyte and multiplex assays by our group[14-16],following by Hu′s group[17-18]and Jiang′s group[19].Recently,we have paid attention to magnetic beads-based immunoassay,hoping to provide a more direct approach on molecules related nanoparticle counting,and extending the value of methodology in various fields of bioassay[20-22].

Herein,we proposed a magnetic beads-based single particle counting strategy for cancer biomarker quantification.Carcinoembryonic antigen(CEA),a 180 kDa glycoprotein that is clinically related to a series of malignancies such as colorectal cancer[23],was chosen as a model analyte.In the methodology,anti-CEA antibody labeled magnetic beads were applied for CEA capturing and subsequent antibody labeled gold nanoparticles(AuNPs)binding.After the magnetic separation of magnetic beads,the remaining AuNPs in the supernatant were diluted and counted by spICP-MS.Under the optimal conditions,the numbers of remaining AuNPs related to the concentration of CEA,providing a three-orders-of-magnitude linear range with a limit of detection(LOD)as low as 0.017 ng/mL.Desirable results were also found in selectivity and simulated sample analysis,making the proposed method promising in cancer diagnosis and prediction.

1 Experimental

1.1 Materials and apparatus

Chloroauric acid hydrate(HAuCl4·xH2O),trisodium citrate,sodium tetraborate,orthoboric acid,4-morpholineethanesulfonic acid(MES),and sodium phosphate buffered saline(PBS)were purchased from Adamas Reagent,Ltd.(Shanghai,China).CEA,capture anti-CEA antibody,and report anti-CEA antibody were purchased from Shanghai Linc-Bio Science Co.Ltd.(Shanghai,China).Bovine serum albumin(BSA),as well as normal fetal bovine serum(FBS),were purchased from Shanghai Sangon Biotechnology Co.Ltd.(Shanghai,China).DynabeadsTM(MyOneTM)carboxylic acid magnetic beads were purchased from Thermo Fisher Scientific Inc.Ultrapure water with 18.24 MΩ·cm came from a Milli-Q water purification system.

Absorption of AuNPs was measured using a Cytation 5 Cell Imaging Multi-Mode Reader(BioTek Instruments,Inc.).Diameter characterization of AuNPs was implemented using a Malvern Zetasizer Nano ZS90(Malvern Panalytical Ltd.).All spICP-MS data were obtained using a NexION 350 inductively coupled plasma mass spectrometer(PerkinElmer,Inc.).Transmission electron microscopy(TEM)images were obtained using a JEM-2010 microscope(JEOL Co.,Japan).

1.2 AuNPs synthesis

50 nm AuNPs were synthesized according to the direct reduction slightly modified from the previous literature[5].Briefly,100 mL 0.01%HAuCl4was heated to boiling for 15 min and was following mixed with 1 mL 1%trisodium citrate solution.Spherical AuNPs formed within 5 min.After keeping boiling for another 15 min and cooling down to room temperature within 6 h,AuNPs were finally purified with a 0.22μm filter and stored under 4oC for further use.

1.3 Preparation of antibody labeled magnetic beads and AuNPs

Carboxylic acid magnetic beads(MBs)were activated by 150 mg/mL EDC and 25 mg/mL NHS under MES buffer.After incubating for 25 min at 27.5℃,the MBs were redissolved with a 20μL CEA coating antibody and 100μL MES.14μL of 10%BSA was added for blocking.After three times washing,MBs were finally redissolved in 200μL PBS buffer containing 1%BSA.

In nanoparticle labeling,AuNPs exhibits a high affinity to disulfide bonds of antibodies.In this work,1 mL boric acid adjusted AuNPs were mixed with 25μg CEA labeling antibody for electrostatic adsorption and were incubated for 1 h at room temperature,then 10%BSA was added for one-hour blocking.As-prepared antibody-AuNPs were redissolved in 1 mL of 1%BSA after centrifugation.

1.4 Single particle counting based immunoassay

In single-particle counting based immunoassay,MBs, CEA,and antibody labeled AuNPs were successively added into a 200μL centrifuge tube.Then,the obtained mixture was settled on a thermal shaker and incubated under 27.5℃.After magnetic separation,the remaining AuNPs probes in the supernatant were diluted twice and introduced into the spICP-MS system for AuNPs counting and CEA quantification.The working instrument parameters were shown in Table 1.

Table 1 Working conditions

2 Results and discussion

2.1 Principle of the single particle counting strategy

Herein,a novel single particle counting protocol was proposed for CEA quantification.As shown in Fig.1,the antibody was immobilized on the surface of MBs for CEA capturing,while report antibody labeled AuNPs were applied for binding with CEA on MBs through sandwich immunoreaction. After magnetic separation,the bound AuNPs on MBs could be enriched at the bottom.The protocol concentrated on the remaining AuNPs in the supernatant which were directly diluted and introduced in the spICP-MS system without sample washing to achieve AuNPs counting.

Fig.1 Single-particle counting strategy for sensitive CEA quantification

2.2 Feasibility of sp ICP-MS based single particle counting strategy

In this work,AuNPs were synthesized and applied as stable tags for CEA quantification.As-prepared AuNPs were characterized by ultraviolet spectrum(UV),TEM,and dynamic light scattering(DLS).By Fig.2A-2C,AuNPs with a uniform size of 50 nm was observed.The UV peak of AuNPs was observed at 533 nm.

Fig.2 Characterization of AuNPs using UV spectrometry(A),TEM(B)and DLS(C)

The key of the proposed method lies in the numbers of AuNPs which can directly linearize with the concentrations of CEA.In other words,AuNPs with suitable diameters could provide not only distinctive signals above dissolved ion signals but also efficient immunoassay.In our previous work,nanoparticle diameter within 30-40 nm of AuNPs has been found to provide desirable homogeneous immunoassay[14-16],nevertheless the partially dissolved ion signals or AuNPs with diameter below 20 nm would increase the influence of background signals on the detective signals.Thus,we adopted 50 nm AuNPs in this work to provide efficient immunoassay with high precision.The relationship between the numbers of AuNPs and+Au197pulses in spICP-MS was investigated.As illustrated from Fig.3A to 3E,distinct Au signals were found above the background where each signal represented a detected Au nanoparticle.In addition,there was a good linear relationship between numbers of AuNPs and+Au197pulses(Fig.3F),meeting the requirement that+Au197pulses in spICP-MS could be utilized to count the numbers of AuNPs and further evaluate CEA concentrations.

Fig.3 Transient signals of AuNPs with different concentrations in spICP-MS(A-E),and a linear relationship between frequency of spICP-MS and concentration of AuNPs(F)

Before immunoassay,AuNPs were labeled with the reported anti-CEA antibodies.UV,DLS,and spICPMS were applied for the characterizations of AuNPs before and after labeling.A gentle redshift of AuNPs peaks was observed in Fig.2A.A certain change of DLS results was attributed to the antibody on the surface of AuNPs which increased light scattering(Fig.2C)[24].Pulses and intensity of AuNPs were also measured by spICP-MS.When the numbers of AuNPs was controlled identical by spICP-MS,it is worth noting from the Fig.4A that the intensity which related to the size of AuNPs negligibly changed[14],demonstrating that there was no obvious aggregation of AuNPs before and after labeling,which could be exploited for upcoming quantification.And then,40 ng/mL CEA was mixed with MBs and antibody AuNPs to explore the immunoassay.Compared with TEM before and after the immunoassay shown in Fig.4B,4C,AuNPs were successfully captured to the surface of MBs through sandwich immunoassay,demonstrating the feasibility of the proposed method.

Fig.4 Pulses and intensity of spICP-MS before and after labeling(A),TEM images of MBs(B)and AuNPs captured on MBs(C)

2.3 Optimization of the immunoassay conditions

The volume of MBs is one of the crucial factors in the proposed immunoassay by spICP-MS and was investigated in this work.According to Fig.5A,10μL volume of MBs was selected to obtain the foremost analytical performance with the highest signal-to-noise ratio.

In this work,the remaining AuNPs probes in the supernatant after magnetic separation were diluted twice for single-particle counting.In the first dilution step,the supernatant was initially diluted 100 times.In the second dilution step optimization illustrated in Fig.5B,+Au197pulses increased initially with the elevation of sample volume and reached the top(100μL),while the intensity of antibody AuNPs(Counts)remained nearly unchanged during 10-100μL.Further increased volume could make several AuNPs counted in each dwell time in spICP-MS and cause pulse decrease as well as intensity increase.The efficiencies of spICP-MS were calculated in Table 2.After comprehensive consideration,a 50μL volume of sample was selected in our subsequent experiments.The total dilution ratio of two-step dilution was 8×103times.

Table 2 spICP-MS efficiencies under varied sample volumes

Fig.5 Optimization of MBs volume by frequency(A)and second dilution steep by both frequency and intensity in the immunoassay(B)

2.4 Quantification of CEA by single particle counting

Different concentrations of CEA were analyzed using the proposed strategy under the optimized conditions by spICP-MS.As depicted in Fig.6A-6B,higher CEA concentration could cause more antibody AuNPs captured on MBs and fewer antibody AuNPs remained in the supernatant,making+Au197pulses decrease.The relationship between pulses and CEA concentration was shown in Fig.6C where the linear range of detectable CEAconcentration was 0.05-20 ng/mL,with a limit of detection(LOD,3σ)as low as 0.017 ng/mL.

Fig.6 Transient signals of antibody AuNPs remained in the supernatant with different concentrations of antigen CEA(A-B),a linear relationship between pulses of antibody AuNPs and concentration of CEA(C),and the selectivity in the single-particle counting strategy

To further verify the selectivity of the proposed method,different interferences were used,and the results were illustrated in Fig.6D.It could be seen that the pulses of CEA were much lower than that of other antigens,indicating that the proposed single particle counting strategy has good selectivity,which was attributed to the antigen-antibody specific recognition.

2.5 Sample analysis

In order to evaluate the analytical capability of the established method in complex matrix,simulated serum samples using FBS were selected for analysis.Concluded from results shown in Table 3,the proposed single particle counting strategy had a comparable accuracy,indicating the capability in real samples analysis.Compared with other methods shown in Table 4,the proposed method was also exhibited desirable outcomes in CEA quantitation.

Table 3 Protocol accuracy in serum samples analysis

Table 4 Comparison of the proposed method with other methods

3 Conclusions

Cancer ranks as the leading threat to human health worldwide,making the in-time diagnosis and evaluation to control morbidity and mortality.Endowed with the ability of single-particle counting,spICP-MS based immunoassay exhibits great potential in sensitive assay within not only heterogeneous but also homogeneous levels.In this work,magnetic beads integrated single particle counting protocol was proposed for CEA quantification.The proposed method concentrated on the remaining antibody labeled AuNPs in the supernatant after immunoassay,which averted the acid digestions or sonication nanoparticles on magnetic beads for detection,providing a more facile procedure during measurements.Under the optimized conditions,the proposed method showed desirable outcomes on CEA detection and simulated sample treatments.We believed that the proposed method could have a promising clinical significance in cancer diagnosis,and serve as a more facile tool in ICP-MS based bioassays.

主站蜘蛛池模板: 免费人成黄页在线观看国产| 97久久精品人人| 國產尤物AV尤物在線觀看| 久久无码av三级| 99re在线视频观看| 久久精品只有这里有| 亚洲视屏在线观看| 国产免费福利网站| 亚洲中文无码h在线观看| 伊伊人成亚洲综合人网7777| 在线国产毛片手机小视频| 欧美成人一级| 亚洲美女高潮久久久久久久| 亚洲性日韩精品一区二区| 国产欧美专区在线观看| 91福利片| 在线亚洲精品自拍| 麻豆国产精品视频| 亚洲无码高清一区二区| 91极品美女高潮叫床在线观看| 色综合狠狠操| 中文字幕亚洲另类天堂| 亚洲欧美精品一中文字幕| 国产18在线| 国产日韩av在线播放| 欧美综合中文字幕久久| 国产午夜一级毛片| 5555国产在线观看| 欧美日韩中文字幕二区三区| 久久这里只有精品2| 亚洲成人黄色在线| 亚洲成人网在线播放| 欧美无遮挡国产欧美另类| 手机看片1024久久精品你懂的| 美女免费精品高清毛片在线视| 国产精品v欧美| 幺女国产一级毛片| 一级做a爰片久久毛片毛片| 日韩二区三区无| 国产成人高清亚洲一区久久| www.91在线播放| 欧美日韩综合网| a欧美在线| 国产精品区视频中文字幕| 亚洲综合色婷婷中文字幕| 蝴蝶伊人久久中文娱乐网| 国产精品自在线拍国产电影| 波多野结衣久久高清免费| 亚洲免费福利视频| 欧美亚洲欧美| 992tv国产人成在线观看| 97免费在线观看视频| 亚洲高清中文字幕| 亚洲Aⅴ无码专区在线观看q| 91福利在线观看视频| 亚洲欧美色中文字幕| 老司机久久99久久精品播放| 久久亚洲国产一区二区| 国产自在自线午夜精品视频| 国产91小视频| 国产精品亚洲精品爽爽 | 亚洲国产天堂久久综合226114| 国产香蕉在线| 久久a毛片| 波多野结衣一区二区三区AV| 青青青草国产| 国产a v无码专区亚洲av| 婷婷亚洲视频| 伊人久久精品无码麻豆精品 | 婷婷六月激情综合一区| 欧美日本在线| 日韩视频免费| 无码免费的亚洲视频| 国产精品网址在线观看你懂的| 精品视频91| 欧美啪啪视频免码| 国内精自视频品线一二区| 精品午夜国产福利观看| 国产乱子伦无码精品小说| 丁香婷婷激情网| av大片在线无码免费| 91国内在线观看|