999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

Orthogonal-triangular decomposition ghost imaging

2022-08-31 09:56:52JinFenLiu劉進芬LeWang王樂andShengMeiZhao趙生妹
Chinese Physics B 2022年8期

Jin-Fen Liu(劉進芬) Le Wang(王樂) and Sheng-Mei Zhao(趙生妹)

1Institute of Signal Processing and Transmission,Nanjing University of Posts and Telecommunications,Nanjing 210003,China

2Nanjing Tech University Pujiang Institute,Nanjing 211222,China

3Key Laboratory of Broadband Wireless Communication and Sensor Network Technology,Ministry of Education,Nanjing 210003,China

Keywords: orthogonal-triangular(QR)decomposition,ghost imaging,correlated imaging

1. Introduction

Ghost imaging (GI), also called correlated imaging, has attracted more and more attention in recent years.[1–21]The traditional GI (TGI) system consists of a signal beam and a reference beam. The signal beam,after illuminating on an object,is collected by a bucket detector without any spatial resolution. The reference beam, which never interacts with the object, is measured by a spatially resolving detector, such as a charged coupled device (CCD) or a complementary metal oxide semiconductor(CMOS)camera. By correlating the reference beam with the bucket signal, the ‘ghost image’ will be recovered in the reference beam. The first GI scheme was achieved based on the entangled-photon pairs, which were generated by spontaneous parametric down-conversion(SPDC).[1,2]Later, it was shown and demonstrated that GI could be realized with classical light sources,such as pseudothermal light,[3,4]true thermal light,[5–7]sunlight,[8]and even the screen of a television.[9]Besides,computational light patterns, produced by spatial light modulator (SLM) or digital mirror device(DMD),can also be used to realize GI.This latter approach is known as computational GI,whose light intensity detected in the reference beam is computed offline.[21]

Whereas, improving the imaging quality of GI is a key project.Recently,a variety of advanced basis illumination patterns based on ghost imaging methods have been proposed to enhance the imaging quality.[22–34]For example, Hadamard basis based ghost imaging and Fourier basis based ghost imaging,[22–31]which constitute a complete orthogonal set,can enhance the imaging quality and shorten the reconstruction time.However,if the speckle patterns are random,there is a high constant background that degrades the imaging quality.Lots of studies focus on improving the quality of the reconstructed images in the GI system with random patterns.[32–34]In 2014,peudo-inverse ghost imaging(PGI)[32]has been presented to enhance the peak signal to noise ratio (PSNR) and reduce reconstruction time for object reconstruction,by computing the pseudo-inverse of the matrix constituted by the row vectors of each speckle field.Later,singular value decomposition ghost imaging(SVDGI)[33]has been proposed to enhance the fidelity of GI by constructing a measurement matrix by using the singular value decomposition (SVD) transform. Besides, Gram–Schmidt ghost imaging[34]has been researched to enhance the efficiency of image acquisition, where a postprocessing method,instead of the pre-modulation method,has been introduced to orthonormalize the patterns in a rotating ground glass scheme by using Gram–Schmidt process. Because these techniques could put the random basis patterns constitute a complete orthogonal set,so they can improve the quality of the reconstructed image in the GI system.

On the other hand,orthogonal-triangular(QR)decomposition technique is a genuine contribution to the field of numerical analysis, where a rectangular matrix can be decomposed into orthogonal matrix and upper triangular matrix.[35]This technique can solve the eigenvalue problem in a very satisfactory way,and reduce the time for standard eigenvalue computations to the time required for a few matrix multiplies.[36–38]Therefore, inspired by the concepts of QR decomposition technique, we propose a novel ghost imaging scheme based on QR decomposition for the case where it is impossible to obtain the orthogonal measurement matrix,named QR decomposition ghost imaging (QRGI). In general, a matrix performed by QR decomposition must satisfy one of the following conditions, and the matrix is square or with full rank. Hence, in the scheme,we construct the new measurement matrix by performing QR decomposition in two circumstances. (1) When the measurement matrix is square,it can be first decomposed into an orthogonal matrixQand an upper triangular matrixR.Then let the off-diagonal values ofRequal to 0.0,the diagonal elements ofRequal to a constantk,wherekis the average of all values of the main diagonal,so the resulting measurement matrix can be achieved. (2)When the measurement matrix is with full rank,then its transpose should be first computed,and followed above QR operation. Finally,we can restore the image of the object by correlating the new measurement matrix and corresponding bucket values. Numerical simulations and experiments verify the feasibility of QRGI.

The remainder of the paper is arranged as follows. QRGI is presented in Section 2. In Section 3, the performance of QRGI is discussed by numerical simulations and practical experiments. Finally,the paper is concluded by Section 4.

2. Theory

Figure 1 shows the schematic diagram of the proposed QRGI scheme. Here, the whole imaging process of TGI system is regarded as a series of matrix operations.[32]In the system,the series of random illumination patternsI1,I2,...,INare generated by a projector and then projected onto the object successively,whereNis the number of speckle patterns. If the transmission coefficient of each illumination pattern is ap×pmatrix,the illumination pattern can be permutated into a 1×p2row vector. Then a new measurement matrix withNrow vectors andPcolumn vectors can be obtained,whereP=p×pis the number of pixels of the pattern. The measurement matrix is recorded as

Fig.1. A schematic diagram of the QRGI scheme.

whereRTRis still an upper triangular matrix. Its diagonal elements represent the effective information for reconstruction.Therefore, we set the off-diagonal values ofRequal to 0.0,the diagonal elements ofRequal to a constantk, wherekis the average of all values of the main diagonal, andRTRin Eq. (8) can be replaced byk2E, whereErefers to an unit matrix. Hence,Eq.(8)can be approximate to

From Eq. (12) we can see that the closer theQQTis to unit matrix, the higher the quality of the reconstructed image is.Therefore, it is in principle that QRGI can get a restored image with a higher fidelity. Noted that the case ofN>Pis not considered since we have restored the object perfectly whenN=P.

3. Results and discussion

In this section,we will verify the proposed QRGI scheme by both numerical simulations and experiments. In order to demonstrate the quality of the reconstructed image, mean square error (MSE) is used as an objective evaluation,[40]which is defined as

whereO(x,y)and ?O(x,y)refer to the original and the reconstructed object respectively,(x,y)is Cartesian coordinate,andPis the number of pixels of the image.

The experimental setup is shown in Fig.2,which includes a projector (DLP LightCrafter 4500), a photodetector (Thorlabs PMM02-1), a data acquisition card(National Instrument USB-6341), and a computer (Intel(R) Core(TM) i3-8145U CPU @ 2.10 GHz; RAM: 8.00 GB). As the bit depth of the projector is limited to 8, the quantization noise is introduced when the values of the random pattern are quantized. The speckle patterns,generated by the projector,are projected onto the target object. The photodetector,placed at the opposite of the object, is used to detect the light intensity reflecting from the object, and the data acquisition card (DAQ) is adopted to perform analogue-to-digital convert.Finally,the computer can reconstruct the object by correlating the speckle patterns and corresponding bucket values.

Fig.2. A schematic diagram of the QRGI scheme experimental system.PD:photodetector. DAQ:data acquisition card.

At first, we compute and display the products ofATAandATQRAQRto reflect which one is closer to unit matrix. We use a randomAof size 64×64 pixels, then constructAQRby our method. Later, we normalize the values ofATAandATQRAQRinto 0–255 grayscale,and graphically display them in Fig. 3, where the insets are the 2D grayscale images of the matrixes, andxandyrepresent the row and column coordinates of their elements,respectively. From the 2D matrix of Figs. 3(a) and 3(b), we can see thatATQRAQRis closer to unit matrix thanATAsince the off-diagonal values ofATAare much larger than those inATQRAQR. Besides, from the 3D maps of Figs. 3(a) and 3(b), we can see thatATAfluctuates violently, the diagonal elements are submerged by the off-diagonal values ofATA,while the off-diagonal values inATQRAQRare much clear,this also demonstrates thatATQRAQRis closer to unit matrix thanATA.Thus,QRGI is theoretically feasible.

Next,we testify the validity of QRGI by numerical simulations and experiments. In accordance with the experimental condition,we normalize the values of random speckle patterns into 0–255 grayscale in simulations,which will introduce the quantization noise. Choosing two pictures as the original objects, one is a grayscale image (‘Cameraman’) and the other one is a binary image(‘Star’). The results are shown in Fig.4,

where Fig. 4(a) are original images, Fig. 4(b) shows the reconstructed images with the size of 32×32 pixels,where the number of measurementsN=1024,and Fig.4(c)displays the reconstructed results with the size of 64×64 pixels, where the number of measurementsN=4096. The first two rows are simulated results, from which we can see that taking the Nyquist limit measurements(equal to the number of the image pixels), QRGI can perfectly reconstruct the object, while the images restored by TGI and DGI are more or less polluted by noise. Besides,taking the grayscale‘Cameraman’of 64×64 pixels for instance,there are two order of magnitude improvement in MSEs values in comparison with those of TGI and DGI. The last two experimental results also show that QRGI has a better performance than that of TGI and DGI. For both binary and grayscale objects,the imaging quality of the reconstructed images of QRGI scheme is better than that of TGI and DGI and corresponding MSEs are smaller, which shows that the proposed QRGI scheme has a better reconstruction performance.

Fig.3. Comparison of ATA and ATQRAQR. (a)ATA,(b)ATQRAQR.Here x: row coordinates of the matrix; y: column coordinates of the matrix.

Figure 5 shows the MSEs curve against the different numbers of measurements by using TGI,DGI and QRGI schemes.Here the object is a binary ‘Star’ image with the size of 64×64 pixels, where Fig. 5(a) shows the simulated results,and Fig.5(b)shows the experimental results. The results indicate that as the number of measurements increases,the MSEs values decrease gradually for three methods, while the proposed QRGI scheme has a more rapidly rate. Compared with TGI and DGI, QRGI scheme could achieve better imaging quality at the same number of measurements.

Fig.4. Simulated and experimental results comparison. (a)Original objects. (b)32×32 pixels,and N=1024. (c)64×64 pixels,and N=4096.

Fig.5.The MSEs curve against the different numbers of measurements by TGI,DGI and QRGI.(a)The simulated results.(b)The experimental results.

Fig. 6. Comparison by using QRGI scheme and SVDGI scheme. (a) The MSEs and reconstruction time curve against different numbers of measurements by using QRGI and SVDGI from experimental results.(b)The computing time curve against the size of the measurement matrix by using SVDGI and QRGI from simulated results.

Figure 6 further shows the MSEs and reconstruction time curve against different numbers of measurements by using QRGI and SVDGI from experimental results, together with the computing time (the time-consuming on the light patterns computation) curve against different numbers of measurements by QRGI and SVDGI from simulated results. Here,a binary ‘Star’ image with the size of 32×32 pixels is selected as the object in Fig. 6(a). The results show that the performance of QRGI and SVDGI are almost the same. Their MSEs values and reconstruction time are very closer at the same number of measurements, which indicates that QRGI can match the performance of SVDGI.Besides,a random rectangle matrix is selected as the measurement matrix to do QR decomposition and SVD transform in Fig. 6(b), from which we can see that with the increase of the size of the matrix,both schemes has a longer computing time, but the proposed scheme costs a less computing time. Therefore,the proposed QRGI scheme has a promising prospect in real applications.

4. Conclusion

In the paper,we have proposed a novel GI scheme to get a better imaging performance with QR decomposition,named QR decomposition ghost imaging, where the whole imaging process of GI system is regarded as a series of matrix operations. The numerical simulations and experimental results have shown that the reconstructed images by using QRGI have a better performance than those reconstructed by using TGI and DGI, and this improvement of imaging quality is without the consumption of physical dimensions of light field. In addition, the proposed QRGI scheme can match the performance of SVDGI,while the proposed QRGI scheme requires a shorter computing time. The proposed scheme is appropriate for the cases where it is impossible to obtain the orthogonal measurement matrix. We believe that the usage of QR decomposition developed in the field of numerical analysis to the GI system provides a way for new GI schemes.

Acknowledgements

Project supported by the National Natural Science Foundation of China (Grant Nos. 61871234 and 62001249), the Postgraduate Research & Practice Innovation Program of Jiangsu Province, China (Grant No. KYCX20 0729), Natural Science Research Project of Higher Education of Jiangsu Province, China (Grant No. 20KJB510030), and Research project of NanJing Tech University Pujiang Institute (Grant No.njpj2020-1-02).

主站蜘蛛池模板: Aⅴ无码专区在线观看| 久久伊人久久亚洲综合| 亚洲一区国色天香| 亚洲国产精品成人久久综合影院| 日本一区二区三区精品AⅤ| 亚洲天堂首页| 精品久久久久成人码免费动漫| www精品久久| 黄色网在线| 久久综合国产乱子免费| 日本一本在线视频| 亚洲首页在线观看| 国产乱子伦视频在线播放| 久久亚洲美女精品国产精品| 麻豆国产精品| 男女性色大片免费网站| 国产精品天干天干在线观看| 久久精品无码专区免费| 成人国产精品2021| 91亚洲视频下载| 亚洲高清无码久久久| 亚洲无卡视频| 一区二区理伦视频| 久久久久国产一区二区| AV不卡在线永久免费观看| 色综合中文字幕| 女同国产精品一区二区| 亚洲an第二区国产精品| 欧美综合中文字幕久久| 欧美日韩国产成人高清视频| 97se亚洲综合不卡| AV无码一区二区三区四区| 九九热免费在线视频| 99视频精品全国免费品| 亚洲日本中文字幕乱码中文| 香蕉伊思人视频| 青青草a国产免费观看| 毛片卡一卡二| 亚洲国产成熟视频在线多多| 国产原创第一页在线观看| 国产精品无码久久久久AV| 国产精品亚洲精品爽爽| 日韩欧美国产精品| 激情综合图区| 在线观看免费人成视频色快速| 精品三级网站| 露脸国产精品自产在线播| 99在线视频免费| 亚洲精品男人天堂| 激情爆乳一区二区| 2048国产精品原创综合在线| 99无码熟妇丰满人妻啪啪| 亚洲视频四区| 免费观看成人久久网免费观看| 国产一区二区人大臿蕉香蕉| 亚洲成人在线网| 丝袜久久剧情精品国产| 久久国产亚洲偷自| 免费又黄又爽又猛大片午夜| 97视频精品全国在线观看| 九九热这里只有国产精品| 国产毛片久久国产| 在线综合亚洲欧美网站| 老司机久久99久久精品播放| 久久黄色小视频| 中文字幕啪啪| 97在线视频免费观看| 国产女人在线| 国产精品刺激对白在线| 91免费精品国偷自产在线在线| 国产成人无码久久久久毛片| 一区二区日韩国产精久久| 成人在线观看一区| 国产鲁鲁视频在线观看| 热思思久久免费视频| 国产精品亚欧美一区二区| 欧洲极品无码一区二区三区| 国产精品三级av及在线观看| 国产区成人精品视频| 国产欧美日韩精品综合在线| 日韩久草视频| 午夜国产大片免费观看|