999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

High-resolution x-ray monochromatic imaging for laser plasma diagnostics based on toroidal crystal

2023-03-09 05:45:48HaoxuanSI司昊軒JiaqinDONG董佳欽ZhihengFANG方智恒LiJIANG蔣勵ShengzhenYI伊圣振andZhanshanWANG王占山
Plasma Science and Technology 2023年1期

Haoxuan SI(司昊軒),Jiaqin DONG(董佳欽),Zhiheng FANG(方智恒),Li JIANG(蔣勵),Shengzhen YI(伊圣振),? and Zhanshan WANG(王占山),?

1 MOE Key Laboratory of Advanced Micro-Structured Materials,Tongji University,Shanghai 200092,People’s Republic of China

2 School of Physics Science and Engineering,Tongji University,Shanghai 200092,People’s Republic of China

3 Shanghai Institute of Laser Plasma,China Academy of Engineering Physics,Shanghai 201800,People’s Republic of China

Abstract Monochromatic x-ray imaging is an essential method for plasma diagnostics related to density information.Large-field high-resolution monochromatic imaging of a He-like iron(Fe XXV)Kα characteristic line(6.701 keV)for laser plasma diagnostics was achieved using a developed toroidal crystal x-ray imager.A high-index crystal orientation Ge 〈531〉 wafer with a Bragg angle of 75.37°and the toroidal substrate were selected to obtain sufficient diffraction efficiency and compensate for astigmatism under oblique incidence.A precise offline assembly method of the toroidal crystal imager based on energy substitution was proposed,and a spatial resolution of 3–7 μm was obtained by toroidal crystal imaging of a 600 line-pairs/inch Au grid within an object field of view larger than 1.0 mm.The toroidal crystal x-ray imager has been successfully tested via side-on backlight imaging experiments of the sinusoidal modulation target and a 1000 line-pairs/inch Au grid with a linewidth of 5 μm using an online alignment method based on dual positioning balls to indicate the target and backlighter.This paper describes the optical design,adjustment method,and experimental results of a toroidal crystal system in a laboratory and laser facility.

Keywords:laser plasma diagnostics,toroidal crystal,monochromatic x-ray imaging

1.Introduction

The plasma produced by the implosion compression of laser inertial confinement fusion(ICF)radiates information-rich x-rays[1–5].As a necessary diagnostic method,high-resolution monochromatic backlight x-ray imaging is of great significance for gaining insight into the physical processes of ICF[6–8].The method uses x-rays generated by ultra-short and ultra-intense lasers as the backlight to probe the state of the implosion core with small-scale and high-density characteristics[9,10].To achieve high backlight brightness,it is necessary to focus the laser beam on the target surface in the range of tens of microns.It is difficult to obtain a sufficient illumination field of view(FOV)to cover the entire plasma region to be diagnosed using traditional small-aperture devices,such as pinhole cameras[11,12]and grazing incidence imaging(e.g.a Kirkpatrick–Baez microscope[13–15]).Pointprojection radiography has been used for large-FOV x-ray imaging in ICF experiments;however,its spatial resolution is determined by the focus size of the backlighter[16,17].A wire or flag target with a diameter of about 10 μm has been widely used to achieve spatial resolution of 10–20 μm[18].

The crystal’s interplanar plane spacing is comparable in magnitude to the x-ray wavelength;thus,it can be used as a natural beam splitter for x-rays[19,20].With their optical properties of large numerical aperture and high spatial and spectral resolution,spherical crystals have been widely used in many laser facilities[21,22].A spherical crystal has the same radius of curvature in the meridional and sagittal directions,which causes severe astigmatism when working at oblique incidence.Therefore,the spherical crystal can only operate at near-normal incidence to achieve high-resolution imaging in two-dimensional directions[23].The detector is placed between the meridional and sagittal focal planes to compensate for astigmatism;thus,it is not easy to achieve the best spatial resolution.Meanwhile,the lattice constants of the crystal materials are fixed.Therefore,the choice of crystal materials and orientations of x-ray imaging for some special energy points is very limited.Through systematic simulation and evaluation,Schollmeieret al[24,25]investigated spherical crystal imaging for self-emission and backlighting measurements ranging from 1 to 25 keV.They recommended selecting high-order crystal material of InAs〈620〉for He-like iron Kαcharacteristic line(6.701 keV)backlighting imaging with a Bragg angle of 75.78°and a poor theoretical resolution of only 9.8 μm.Additionally,effective shielding of the background signals in near-normal incidences is a difficult technical problem to overcome.

Compared with spherical crystals,toroidal crystals have different radii of curvature in the meridian and sagittal directions,thereby eliminating severe astigmatism present in non-normal incidences and expanding the selection of crystal materials and orientations,as well as significantly improving spatial resolution[26].Uschmannet al[27]first developed toroidal crystals of Si 〈311〉 and Ge 〈311〉 for He-like argon Kβline(3.1 keV)imaging with an online-calibrated resolution of more than 15 μm.Jianget al[28]reported a four-channel toroidal crystal imager of Ge 〈400〉for Ti Kαline(4.51 keV)imaging with an offline calibrated resolution of 4–10 μm.Meanwhile,various types of x-ray spectrometers based on toroidal structures have been developed[29,30].However,there is still a lack of online diagnostic applications of toroidal crystals in laser facilities with a high spatial resolution at the 5 μm level,as well as its precise offline assembly and alignment methods.In this paper,we present a toroidal crystal x-ray imager for hydrodynamic instability growth measurement using side-on backlight imaging of a sinusoidal modulation target.The spatial resolution was further improved to a range of 3–7 μm within the FOVs of the mm class.Furthermore,precise offline assembly and alignment methods were developed.

2.Optical design

In this work,a single crystal of Ge was used as a diffractive material due to its relatively high integrated efficiency,which is suitable for experiments in a kJ-class laser facility.The iron foil was selected as the backlight target,and a He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV)was selected as the working energy because of higher x-ray yield compared to the Kαline(6.404 keV)and moderate penetration thickness to the side-on modulation target.The focal distances of bentcrystal imaging in the meridian and sagittal directionsfmandfscan be given by the formula[31]:

whereRmandRsare the radii of curvature of the substrate in the meridian and sagittal directions,respectively;θ is the Bragg angle of the crystal center.For the toroidal crystal imager,as shown in figure 1,the focal distances in two directions are equal by regulatingRmandRs,conforming to the following formula so that the astigmatism was effectively corrected:

Additionally,the Bragg angle of toroidal crystals should be selected in a range of 60°–80°because the incident x-rays have a certain penetration depth to the crystal material,especially for x-rays above several keV.In this work,the crystal orientation of Ge〈531〉with a lattice constant of 0.956 ? was selected,and the Bragg angle on 6.701 keV x-ray energy was 75.37°,which fits the required angular range of 60°–80° and has a higher integration efficiency than an α-quartz crystal.

After obtaining the working Bragg angle of the toroidal crystal,the ratio of the radii of curvature of the toroidal mirror in the meridian and sagittal directions is fixed.Table 1 presents the initial structure parameters of the toroidal crystal of Ge 〈531〉.By considering the constraints of the experiment space and the pixel size of 25 μm×25 μm of the image detector(Image Plate,FUJI Film,BAS1025 in this paper),the curvature radiusRmwas set to 250 mm and magnification was about 10 times,and the limited spatial resolution determined by the detector pixel was about 5 μm at this time.The object distanceufrom the object to the crystal is about 133 mm,which is sufficient to place the diagnostic device and reduce the interference of splashing debris,and the image distancevwas set to 1310 mm.

Table 1.The initial structure parameters of the toroidal crystal Ge 〈531〉.

3.Assembly and alignment

The crystal was prepared by directly attaching a doublepolished Ge wafer with a diameter of 12 mm and a thickness of about 100 μm to the toroidal substrate made of K9 glass by optical contact of the molecular force.The wafer replicated the surface shape of the toroidal substrate to ensure good replication.They were polished to obtain a roughness below 1 nm and ultrasonically cleaned to effectively strip the solvent and particles remaining on the wafer and toroidal substrate.From an instrument alignment and installation perspective,the change in the backlighter position causes deviation of the illumination area on the toroidal crystal surface,thereby reducing the brightness of the central FOV and having a serious impact on the spatial resolution.Therefore,it is essential to simultaneously ensure the position accuracy between the backlighter,object point,and toroidal crystal.Unlike the current common installation and adjustment methods based on visible light,this paper proposes an offline assembly method with toroidal crystals using laboratory x-ray imaging to determine the best object–image relationship.Since a conventional iron x-ray tube cannot produce a He-like Kαline(6.701 keV),we use a Gd x-ray tube with very close energy(Gd Kαline 6.713 keV)as the offline source for crystal alignment.There is a difference of only about 12 eV between the two characteristic lines.Meanwhile,the Gd Kαline is completely within the spectral bandwidth of the He-like iron Kαline,which is confirmed by the later measurement results of the bent-crystal spectrometer.The focal spot of the Gd x-ray tube,with a size of about 1.0 mm×1.0 mm,was placed at about 70 mm away from the grid,with an aperture angle of about 0.014°for each object point.Figure 2(a)shows the x-ray image of a 600 line-pairs/inch grid(Gilder,G600HSS)backlit using the Gd x-ray tube after fine-tuning.The image was acquired by an x-ray chargecoupled device(CCD,Princeton Instruments:PIXIS-XO-1024B)with a resolution of 1024 pixels×1024 pixels and a pixel size of 13.5 μm×13.5 μm.A reference hole of about 150 μm in diameter was drilled in the grid to provide the position calibration of the FOVs.

Figure 1.The optical path structure of the toroidal crystal x-ray imager.

Figure 2(a)shows the toroidal crystal images of the grid with a linewidth of 5–6 μm on the entire detection surface.It can be seen that the gridline clarity at four corners of figure 2(a)was worse than that at the image center,which was mainly caused by the following.Firstly,the geometric aberration increases gradually with the FOV deviation.Secondly,the imaging of the four-corners position was formed by x-ray reflection on the surface edge area of the toroidal crystal;the surface quality of the crystal edge was worse than that of the center region after optical polishing.

Figure 2(b)shows the intensity change in figure 2(a)in the horizontal direction(corresponding to the meridional direction).Taking the gridline as the knife-edge,the spatial resolution of the toroidal crystal in different FOVs can briefly be estimated from the intensity change.In this work,we chose an intensity change of 20%–80%(figure 2(c))to evaluate the spatial resolution,and the measured value is shown in figure 3(a).The spatial resolution in the full FOV(about 1.3 mm)is mostly 3–7 microns.The length of the error bar was 1.35 μm,which is equivalent to the spatial resolution corresponding to one CCD pixel.The limit resolution of the toroidal crystal restricted by the CCD detector is about 2.7 μm,corresponding to two pixels.If a CCD with a smaller pixel was used,the spatial resolution could be further improved.Figure 3(b)shows the resolution calibration results in the vertical direction(corresponding to sagittal directions),which is slightly worse than that in the meridional direction but still reaches 3–7 μm within an FOV of about 1 mm.The magnification of the toroidal crystal can be calibrated by dividing the grid period in figure 2(a)by the results measured using structural equation modeling.The actual magnification and image point spacing can also be calibrated in figure 2,which are approximately 9.93 and 10.38 times in the meridian and sagittal directions,respectively.

Figure 2.(a)Offline imaging results of Ge〈531〉toroidal crystal using a Gd x-ray tube.(b)The intensity profile in the horizontal direction.(c)Resolution evolution criterion by the intensity change of ‘20%–80%’.

Figure 3.Calibrated spatial resolution of the Ge〈531〉toroidal crystal via offline imaging experiments in the(a)meridional and(b)sagittal directions.

Figure 4.(a)The mechanical structure of the toroidal crystal after assembly,and(b)an enlarged view of the aiming part.

The rapid installation of the toroidal crystal in the laser facility is another important issue that needs to be considered to improve experimental efficiency.In this work,the dual positioning ball method,previously applied to the grazing Kirkpatrick-Baez microscope,was used to simultaneously indicate the ideal backlighter and object position of the toroidal crystal[32]and then realize the switch of the toroidal crystal system from the offline laboratory to the laser facility.Figure 4(a)shows the final mechanical structure of the toroidal crystal system after assembly,which includes the toroidal crystal,an aiming part,and an imagerecording part.As shown in figure 4(b)of the enlarged view of the aiming part,we use an object positioning ball with a diameter of 500 μm to replace the reference hole in figure 2(a)using two orthogonal industrial cameras.Then,the optical axis of the toroidal crystal imaging was indicated by aiming at the center of the simulated sphere and toroidal crystal using an internal focusing telescope.At this time,the axis of the internal focusing telescope is equivalent to the optical axis of the toroidal crystal.Finally,the center of the backlighter positioning ball was adjusted to the axis of the internal focusing telescope.Meanwhile,the distance between the two positioning balls was aligned using a Vernier caliper to approximate 15.0 mm,consistent with the actual application conditions,where the diode laser indicates the image position to place the image plate.The two positioning balls and diode laser were connected to the toroidal crystal with the linear guides(HIWIN,MGN15P),and can be reattached with highly reproducible accuracy of about 20 μm.

Figure 5.(a)A sample structure of the sinusoidal modulation target,and(b)its experimental image acquired by the Ge〈531〉toroidal crystal with the iron backlighter at SG-II U.

4.Experiment with plasma backlighter

The toroidal crystal x-ray imager has been successfully tested in side-on backlight imaging of a sinusoidal modulation target in a hydrodynamic instability growth experiment in the Shenguang-II Upgrade(SG-II U)laser facility.The experiment’s optical path was arranged according to figure 4.One of the eight laser beams(1 ns,3ω,800 J),with a focal spot of 300 μm diameter smoothed by a continuous-phase plate,was used to irradiate the iron foil to produce a He-like x-ray backlighter.The distance between the backlighter and the target is 15 mm,so that the aperture angle for each object point is about 0.020°.As shown in figure 5(a),a target with two layers is used in the experiments.A 20 μm thick C8H8layer was conglutinated with a 30 μm Al layer.At the C8H8/Al interface,a perturbation of 55 μm wavelength and 1.5 μm amplitude had been machined into the Al.The C8H8layer is nearly transparent to the 6.701 keV backlight x-rays,whereas the Al layer is opaque to it.Thus,we can obtain obvious contrast at the interface.A square grid with 1000 line-pairs/inch and a linewidth of 5 μm was placed next to the sinusoidal modulation target to calibrate the spatial resolution.Figure 5(b)shows the experimental image acquired by the image plate with a pixel size of 25 μm×25 μm.The central FOV with the best spatial resolution is the position where the grid meets the sinusoidal target.As the FOV deviates,the spatial resolution gradually deteriorates,consistent with the results of offline calibration.The effective FOV range in the horizontal direction is about 700 μm,which is mainly limited by the spectral width of the x-ray backlighter.The grid lines can be clearly observed in the effective FOV,indicating that the spatial resolution of the toroidal crystal is close to the level of the grid linewidth of about 5 μm.In addition,the aperture angle for each object point in the online experiment(0.020°)was larger than that in the offline experiment(0.014°),and the pixel size of the image plate(25 μm × 25 μm)was bigger than that of the x-ray CCD(13.5 μm × 13.5 μm);therefore,the overall spatial resolution of figure 5(b)has a certain decrease compared to figure 2(a)obtained from the offline experiment.This phenomenon can be eliminated by using an x-ray backlighter with a smaller focal spot and an image detector with a smaller pixel size in subsequent physical experiments.The actual magnification of the toroidal crystal can also be calibrated by dividing the distance between adjacent grid lines on the image by the period width of the grid.These magnifications are approximately 9.90 and 10.32 times in the meridian and sagittal directions,respectively,which are very close to the design value.

5.Conclusions

A large-field high-resolution x-ray imager of toroidal crystal Ge〈531〉was developed for backlight imaging of the He-like iron(Fe XXV)Kαcharacteristic line(6.701 keV).The Ge〈531〉 wafer and toroidal substrate were fabricated by ultrasmooth polishing.Then,it was ultrasonically cleaned before crystal bending to ensure the surface shape.Spatial resolution of 3–7 μm within an object field larger than 1.3 mm was obtained in the offline calibration experiment.We employed a precise alignment method based on double positioning balls to reduce the online installation difficulty and improve the experimental efficiency.The side-on backlight imaging of sinusoidal modulation targets with a calibrated resolution of about 5 μm was completed by the toroidal crystal at the SG-II U laser facility.The toroidal crystal x-ray imager can be further extended to plasma diagnostics at other x-ray energies by selecting appropriate crystal materials,crystal orientations,and substrate curvature radius.

Acknowledgments

This work is supported by National Natural Science Foundation of China(No.11805212)and National Key Research and Development Program of China(No.2019YFE03080200).

主站蜘蛛池模板: 国产中文在线亚洲精品官网| 香蕉蕉亚亚洲aav综合| 日韩毛片在线视频| 狠狠综合久久久久综| 91精品人妻互换| 国产永久无码观看在线| 亚洲乱强伦| 精品人妻AV区| 亚洲成综合人影院在院播放| 久久久久无码精品| 中文字幕人成乱码熟女免费| 日本国产精品一区久久久| 精品成人免费自拍视频| 欧美怡红院视频一区二区三区| 草逼视频国产| 国产精品久久精品| 狠狠亚洲五月天| 91精品国产一区自在线拍| 久久精品一卡日本电影| 欧美天堂久久| 色老头综合网| 中文字幕1区2区| 亚洲第一区精品日韩在线播放| 欧洲成人在线观看| 欧美三级不卡在线观看视频| 久久国产精品波多野结衣| 国产成人1024精品| 第一页亚洲| 国产高颜值露脸在线观看| 国产视频a| 国产91小视频在线观看| 国产特级毛片| 色老二精品视频在线观看| 中文字幕在线不卡视频| 浮力影院国产第一页| 欧美a级完整在线观看| 日韩无码白| 精品人妻一区无码视频| 国产精品久久久久久久久久98 | 伊人查蕉在线观看国产精品| 亚洲无码高清一区二区| 欧美午夜视频在线| 亚洲天堂网视频| 国产微拍精品| 欧美另类视频一区二区三区| 在线精品亚洲一区二区古装| 国产美女精品人人做人人爽| 精品国产免费第一区二区三区日韩| 3344在线观看无码| 国产亚洲欧美日本一二三本道| 亚洲国产成人久久77| 暴力调教一区二区三区| 五月婷婷导航| 日韩欧美中文| 天堂岛国av无码免费无禁网站| 欧美在线伊人| 国产特级毛片aaaaaaa高清| 香蕉eeww99国产在线观看| 日本成人精品视频| 久久久久久午夜精品| 亚洲中文无码h在线观看| 欧美精品成人一区二区在线观看| 女人毛片a级大学毛片免费| 精品无码一区二区三区电影| 久久精品aⅴ无码中文字幕| 色综合天天综合中文网| 日韩经典精品无码一区二区| 国产亚洲精品自在线| 久久久久久尹人网香蕉| 国产精品深爱在线| 99国产精品一区二区| 天天躁夜夜躁狠狠躁躁88| 一级片一区| 国产成人精品男人的天堂| 40岁成熟女人牲交片免费| 亚洲成aⅴ人在线观看| 亚洲国产日韩视频观看| 在线99视频| 午夜视频免费试看| 亚洲综合色婷婷中文字幕| 欧美日韩在线成人| 日韩无码黄色网站|