摘"要:以降低變電站通信網絡時延為目標,基于時間敏感網絡設計了一種低時延控制方法。首先,在變電站通信網絡的站控層和過程層中,利用時間敏感網絡交換機組建時間敏感子網絡,再將不同交換機終端辨識為多個線性參數模型。然后,利用模糊控制方法控制交換機同步時鐘的誤差,根據模糊C均值聚類方法確定低時延控制的模糊規則前件,利用時間敏感網絡的參數辨識獲取模糊規則后件。最后,依據模糊控制前件與后件,結合模糊控制與廣義預測控制,實現時間敏感網絡時延的反饋校正。實驗結果表明,采用該方法控制變電站通信網絡時延量后,網絡通信最大時延被控制在100"μs以內,最大時延抖動被控制在20"μs以內,說明該方法有效實現了設計預期。
關鍵詞:時間敏感網絡;變電站;通信網絡;低時延控制;交換機;模糊控制方法
中圖分類號:TM73""""""文獻標識碼:A
Low"Time"Delay"Control"Method"of"Substation"Communication
Network"Based"on"Time"Sensitive"Network
FENG"Yu1,"WANG"Bolong1,"CHENG"Shuo1,"NI"Jihong1,"DONG"Simeng2
(1.State"Grid"Liaoning"Information"and"Communication"Company,"Shenyang,"Liaoning"110006,"China;
2.State"Grid"Yingkou"Electric"Power"Supply"Company,"Yingkou,"Liaoning"115002,"China)
Abstract:With"the"goal"of"reducing"the"delay"of"substation"communication"network,"this"paper"designs"a"low"delay"control"method"based"on"time"sensitive"networks."Firstly,"in"the"station"control"layer"and"process"layer"of"the"substation"communication"network,"time"sensitive"network"switches"are"used"to"construct"time"sensitive"subnetworks,"and"different"switch"terminals"are"identified"as"multiple"linear"parameter"models."Then,"fuzzy"control"method"is"used"to"control"the"synchronization"clock"error"of"the"switch,"and"fuzzy"rule"antecedents"for"low"latency"control"are"determined"based"on"fuzzy"Cmeans"clustering"method."Fuzzy"rule"antecedents"are"obtained"through"parameter"identification"of"time"sensitive"networks."Finally,"based"on"the"pre"and"post"components"of"fuzzy"control,"combined"with"fuzzy"control"and"generalized"predictive"control,"feedback"correction"of"time"sensitive"network"delay"is"achieved."The"experimental"results"show"that"after"using"this"method"to"control"the"delay"of"the"substation"communication"network,"the"maximum"delay"of"network"communication"is"controlled"within"100"μs,"and"the"maximum"delay"jitter"is"controlled"within"20"μs,"indicating"that"this"method"effectively"achieves"the"design"expectations.
Key"words:timesensitive"network;"substation;"communication"network;"low"delay"control;"switch;"fuzzy"control"method
智能變電站是智能電網的重要組成部分[1]。變電站通信網絡是智能變電站測量、控制保護的基礎。伴隨智能變電站IEC"61850通信標準的不斷完善,變電站對通信質量要求更高,通信網絡時延直接影響著變電站的運行穩定性。
在現代化通信技術不斷發展的當下[2-4],電力通信網絡從傳統的固定電話通信方式,逐步發展為多元化綜合通信方式。變電站通信網絡的數據流量呈指數增長,常規的通信網絡已難以滿足過多業務量的通信實時性需求[5-7],高性能通信網絡的研究已經迫在眉睫。……