999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

基于香豆素的增強型銅離子熒光探針及其在細胞成像中的應用

2019-10-09 08:50:16張長麗何鳳云劉少賢柳閩生
無機化學學報 2019年10期
關鍵詞:南京

張長麗 張 虹 何鳳云 楊 慧 劉少賢 柳閩生

(南京曉莊學院環境科學學院,南京市先進功能材料重點實驗室,南京 211171)

0 Introduction

Fluorescentsensing ofchemicalspecies of biological and environmental significance by fluorescence spectroscopy has emerged as an attractive field for scientists,especially inspired by the development of confocal microscope and optical imaging techniques[1-7].As the third most abundant transition metal ions in the human body,copper ions play important roles in various biological processes,and maintaining its homeostasis is critical for development of living organisms[8-12].The disturbed homeostasis of copper ions can result in severe cell damage and further lead to many diseases such as Menkes syndrome,Wilson disease,and Alzheimer disease[13-21].Due to its essential toxic nature,long-term exposure to high levels of copper has been reported to induce the liver and kidney damage[22].According to the World Health Organization(WHO)International Standard for drinking water,the maximum acceptable level of copper in drinking water is 30 μmol.L-1[23].Considering the important roles of copper in physiological processes and its high toxicity,development of specific fluorescentprobesforsensitivecopperdetection,especially in environmental and physiological conditions is of great significance.

To date lots of fluorescent probes have been reported for Cu2+detection based on two main mechanisms:coordination of receptor with Cu2+[24-34]and Cu2+-triggered specific reactions[35-47].Due to the paramagnetic nature of Cu2+,Cu2+coordination often results in fluorescence quenching.Fluorescence"turnoff"signals are usually less sensitive and generate false-positive results[24,48],which is a disadvantage for practical application. Such obstacles can be eliminated by employing reaction-based probes,which achieve fluorescence "turn-on"response and offer high selectivity by reacting specifically with Cu2+to generate fluorescent products.However,few fluorescence turn-on Cu2+probes have been reported[49-54],which make the development of new fluorescence turn-on Cu2+probes highly desired.

In this paper,Cou-P,a turn-on fluorescent probe for Cu2+sensing based on a mechanism of Cu2+-coordination-induced hydrolysisofhydrazideswas developed.Cou-P exhibits a selective and sensitive emission turn-on response to Cu2+and features visible light excitation and emission profiles.Moreover,its turn-on imaging ability for intracellular Cu2+has been confirmed in human breastadenocarcinomacells(MCF-7 cells)using a confocal microscope.

The synthesis route for Cou-P was depicted in Scheme 1.Cou-P was synthesized by reacting of 7-(diethylamino)-coumarin-3-carbonyl chloride and 2,2′-(hydrazonomethylene)dipyridine in the presence of Et3N in a high yield (85%).It was well characterized by1H,13C NMR and ESI-MS(Supporting Information).

Scheme 1 Synthesis of Cou-P

1 Experimental

1.1 General procedures

All chemicals and solvents were of analytical grade or spectroscopic grade and were used without further purification.Dichloromethane was refluxed with calcium hydride and distilled at ambient pressure.1H NMR and13C NMR spectra were recorded on a Bruker DRX-300 spectrometer or Bruker DRX-500 spectrometer with TMS as internal reference in CDCl3.Mass spectrometric data were determined with LCQ ESI-MS Thermo Finnigan mass spectrometer.Absorption spectra were measured on a Shimadzu UV-3100 UV-Vis-NIR spectrophotometer.The fluorescence spectra were recorded with an AMINCO Bowman series 2 luminescence spectrophotometer (cuvette,1 cm)with a xenon lamp as the light source.

1.2 Synthesis of Cou-P

A solution of compound 1 (200 mg,0.72 mmol)in CH2Cl2(5 mL)was slowly added to a solution of compound 2 (143 mg,0.72 mmol)and Et3N (80 mg,0.68 mmol)in CH2Cl2(10 mL).The reaction mixture was stirred at room temperature for 24 h.The mixture was washed with water(3X15 mL).The organic layer was dried on MgSO4and filtered,and the filtrate was concentrated todryness.Thecrudeproductwas purified by column chromatography (silica gel,VMeOH∶VCH2Cl2=1∶10,Rf=0.4),and pure compound Cou-P was obtained as an orange solid(270 mg)in 85%yield.1H NMR(400 MHz,CDCl3):δ 8.97(d,1H,J=4.0),8.83(s,1H),8.58(d,1H,J=4.0),8.28(d,1H,J=8.0),7.86~7.78(m,2H),7.52(d,2H,J=8.0),7.46~7.30(m,2H),7.28~7.31(t,1H,J=4.0),6.63~6.66(dd,1H,J1=2.4,J2=2.0),6.47(s,1H),3.42~3.48(q,4H,J1=7.6,J2=6.8),1.21~1.253(t,6H,J=7.2);13C NMR(100 MHz,CDCl3):δ 161.92,161.04,158.12,156.23,153.04,151.85,149.45,149.25,149.07,148.59,136.86,136.82,131.53,126.13,124.18,124.14,123.70,110.23,110.16,108.82,96.84,45.30,12.59.ESI-MS (positive mode):Calcd.905.90,Found:905.08 for[2M+Na]+.Element analysis Calcd.for C25H23N5O3(%):C,68.01;H,5.25;N,15.86.Found(%):C,68.12;H,5.46;N,15.78.

1.3 Spectroscopic measurements

All the solvents were of analytic grade.The stock solution of Cou-P was prepared in CH3OH(1.04 mmol.L-1).Forspectroscopic determination,the stock solution was diluted with PBS to the desired concentration.The stock solutions of metal ions were prepared by dissolving Cu(NO3)2,CoCl2.6H2O,NiCl2.6H2O,HgCl2,MnCl2,Fe(NO3)3.9H2O,FeSO4.7H2O,AgNO3,PbCl2,Zn(NO3)2.7H2O,CdCl2.2.5H2O,KCl,CaCl2,NaCl,MgCl2.6H2O with doublydistilled water.Fluorescence measurements of Cou-P (10 μmol.L-1)were performed with 4 nm slit for excitation and 4 nm slit for emission.The UV-Vis titration of Cou-P was carried out by adding aliquots of 2.5 μL of Cu(NO3)2aqueous solution (1.2 mmol.L-1)to 3 mL of probe solution (10 μmol.L-1)in a cuvette.The spectra were recorded after the solution was completely mixed.The fluorescence titration of Cou-P was also carried out by adding aliquots of 2.5 μL of Cu(NO3)2aqueous solution(1.2 mmol.L-1)to 3 mL of sample solution(10 μmol.L-1)in a cuvette.The measurements were carried out in 2 min after the addition.All experiments were carried out at 298 K.

1.4 Cell imaging

MCF-7 cellswere cultured in Dulbecco′s Modified Eagle Medium supplemented with 10%fetal bovine serum,penicillin(100 unit.mL-1),streptomycin(100 mg.mL-1)and 5%(V/V)CO2at 37℃.After removing the incubation media and rinsing with 1X PBS (0.01mol.L-1)for three times.The MCF-7 cells were incubated with Cou-P(20 μmol.L-1)for 30 min at 25℃.Then the cells were washed three times with 1XPBS and imaged with Zeiss LSM-710 microscope equipped with a 63Xoil-immersion objective.For the imaging ofMCF-7 cells upon incubation with exogenous Cu2+,the exogenous Cu2+was introduced by incubating the cells with Cu(NO3)2(200 μmol.L-1)solution for 5 h at 25℃.The excitation wavelength of Cou-P used in experiment was 405 nm,while the filter was 420~520 nm.

2 Results and discussion

2.1 Sensing properties

The sensing ability of probe Cou-P for Cu2+was investigated using fluorescence spectroscopy in HEPES buffer solution (50 mmol.L-1,0.1 mol.L-1KNO3,pH=7.2).As shown in Fig.1,the probe Cou-P itself showed relatively weak fluorescence at 497 nm(Ф=0.005)when excited by 460 nm.However,upon addition of 5 eq.of Cu2+,probe Cou-P exhibited a significant fluorescence enhancement at 464 nm (Ф=0.068),indicating that Cou-P could be efficiently responded in the presence of Cu2+.

Excitation wavelengths are 460 nm for Cou-P and 400 nm for adding 5 eq.Cu2+,respectivelyFig.1 Fluorescence spectra of Cou-P(10 μmol.L-1)andthe corresponding hydrolysis product after adding 5 eq.Cu2+in HEPES buffer(50 mmol.L-1,0.1 mol.L-1KNO3,pH 7.2)

2.2 Mechanism study

Due to few reports on the reaction copper probes of hydrazide derivatives,the recognition mechanism of probe Cou-P for Cu2+was investigated in detail.First,Cu2+binding behaviour in Cou-P was investigated by fluorescent and UV-Vis titration experiments.The UV-Vis titration experiment demonstrates that free Cou-P has two main absorption bands centering at 454(ε=2.8X104L.mol-1.cm-1)and 318 nm,which can be assigned to ICT and π-π* transition bands,respectively (Fig.2a).When Cu2+was added,distinct reduction ofthe formerband can be observed accompanied by the evident bathochromic shift to 474 nm,suggesting the increased coplanarity of electrondonating group induced by Cu2+binding.Similar change was also observed for the latter band,yet the band shift is much less pronounced.The clear isosbestic points at 471,396 and 339 nm imply the undoubted conversion of free Cou-P to a copper complex.The titration profile based on the former band shows that the absorbance descends linearly with cCu2+at the ratio of cCu2+

/cCou-P≤1.Higher cCu2+does not lead to any further evident change of isosbestic points at 471,396 and 339 nm,suggesting a 1∶1 stoichiometry for the copper complex.The result obtained from fluorescence Job′s plot also confirms the 1∶1 Cu2+binding stoichiometry (Supporting information,Fig.S1).Cou-P/Cu2+complexes can remain stable for at least 120 min at pH 7.2 (Fig.S2).However,after the ratio of cCu2+/cCou-Pattained 1,upon addition of another 0.1 eq.Cu2+to the solution of Cou-P/Cu2+complex,a new absorption band centered at 414 nm appeared and the intensity enhanced gradually in a time-dependent manner;at the same time,the absorption band at 474 nm exhibited decrease(Fig.2b).The clear isosbestic points at 454 nm imply the undoubted conversion of Cou-P/Cu2+complex to another compound.Normalized emission spectra of 3-(carboxylic acid)-7-(diethylamino)-coumarin(Cou-COOH)and Cou-P incubated with 1.1 eq.Cu(NO3)2for 80 min overlaped well,Cou-P/Cu2+complex may convert to Cou-COOH(Fig.S3).

Further fluorescence titration of Cou-P by Cu2+shows similar phenomena.Titration of Cou-P by Cu2+exhibits a linear emission decrease with cCu2+,and the fluorescence of Cou-P was quenched efficiently when the cCu2+

/cCou-Pratio attained 1 (Fig.3a).However,after the cCu2+

/cCou-Pratio attained 1,upon addition of another 0.1 eq.Cu2+to the solution of Cou-P/Cu2+complex,a new excitation band centered at 403 nm appeared and the intensity enhanced gradually in a time-dependent manner(Fig.3b).After 300 minutes,the fluorescence intensity at 403 nm (I403)was reached its maximum.Further addition of EDTA could not eliminate the fluorescence (Fig.S4).This result demon-strates that Cou-P/Cu2+complex might have undergone Cu2+-catalyzed chemical reactions.

To further verify the recognition mechanism of probe Cou-P for Cu2+,the reaction product of Cou-P with Cu2+was characterized by the ESI-MS spectrometry.After addition of 1.1 eq Cu(NO3)2for 60 min,ESI-MS of Cou-P shows a peak assigned to[Cou-PH++Cu2++CH3OH]+(Fig.S5).After 300 min,there are three prominent peaks,341.5 assigned to[3-H++Cu2++H2O]+,171.42 assigned to [(3+Cu2++H2O)/2]+,251.33 assigned to[4+MeOH+Na+]+,respectively(Fig.4).The isotopic distribution of peak at 341.5 matches with the results of ISOPRO 3.0 simulation,which further indicates the reaction product of Cou-P with Cu2+.This result is consistent with the experimental results of spectroscopy.

Fig.2 (a)Absorbance spectra of 10 μmol.L-1Cou-P in HEPES buffer obtained by adding 0~1.6 eq.Cu(NO3)2(1.2 mmol.L-1)solution;(b)Time-dependent UV-Vis absorption spectra of 20 μmol.L-1Cou-P in HEPES buffer obtained by adding excessive Cu(NO3)2(100 μmol.L-1)solution

Thus,the coordination of Cu2+to picolinic ester in probe Cou-P is essential for the Cu2+-promoted hydrolytic cleavage of Cou-P to Cou-COOH(3).Based on the above results,a detailed recognition mechanism of probe Cou-P for Cu2+was proposed as shown in Scheme 2.

Fig.3 (a)Emission spectra of 10 μmol.L-1Cou-P in HEPES buffer obtained by adding aliquots of 2.5 μL Cu(NO3)2(1.2 mmol.L-1)solution;(b)Time-dependent fluorescent excitation spectra of 10 μmol.L-1Cou-P in HEPES buffer after addition of 1.1 eq.Cu(NO3)2

Fig.4 (a)ESI-MS of Cou-P in MeOH/H2O(1∶1,V/V)after addition of 1.1 eq.Cu(NO3)2for 5 h;(b)Corresponding simulated one for[3-H++Cu2++H2O]+;(c)Determined isotopic distribution patterns of the peak with m/z of 341.50

Scheme 2 Proposed mechanism of Cu2+-catalysed reaction of Cou-P

2.3 Cu2+detection selectivity

Selectivity is a crucial parameter to assess the performance of the developed probes.Therefore,the selectivity experiments of Cou-P were extended to a variety of biological-related species including common cations(K+,Na+,Mg2+,Ca2+,Co2+,Ni2+,Fe2+,Fe3+,Hg2+,Mn2+,Zn2+,Cd2+,Pb2+and Ag+).As shown in Fig.5a,only introduction of Cu2+could cause apparent fluorescence intensity changes of the probe Cou-P solution,most of the tested cation did not induce any emission enhancement at 403 nm.According to the value of I403/I460,Cu2+can induce 13-fold fluorescence enhancement,and Co2+and Ni2+also induce very minor enhancement due to fluorescence quenching at 460 nm (Fig.5b).Moreover,the abundant metal cations in natural water such as Na+,K+,Ca2+and Mg2+do not result in distinct emission either.This provides probe Cou-P the advantage in sense Cu2+in samples containing abundant Na+,K+,Ca2+,and Mg2+,such as living cells.

Fig.5 (a)Excitation spectra of Cou-P(10 μmol.L-1)in the presence of various metal ions in HEPES buffer(50 mmol.L-1,0.1 mol.L-1KNO3,pH 7.2);(b)Ratio of fluorescence intensity at 403 and 460 nm of 10 μmol.L-1Cou-P induced by different metal ions in HEPES buffer

2.4 Cell cytotoxicity and confocal fluorescence imaging

The cytotoxicity of probe Cou-P in MCF-7 cells was evaluated by MTT assays with the concentration of the probe ranging from 2 to 50 μmol.L-1(Fig.S6).The results show that Cou-P is of low cytotoxicity to cultured cells and should be safe when used for bioimaging of Cu2+.

Based on the favorable features ofCou-P including visible emission,high selectivity for Cu2+and low toxicity,the potential utility of Cou-P to visualize Cu2+in living cells was investigated.As shown in Fig.6,MCF-7 cells incubated with Cou-P(10 μmol.L-1)alone for 30 min at 37℃ exhibited no observable fluorescence.However,when cells were further incubated with Cu2+(200 μmol.L-1)for 300 min at 37℃,remarkable intracellular fluorescence could be observed.These results indicate that probe Cou-P is permeable to cell membrane and suitable for imaging Cu2+in living cells.

Fig.6 Confocal fluorescence images of intracellular Cu2+in MCF-7 cells with Cou-P-staining:(a)Bright-field transmission images;(b)MCF-7 cells incubated with Cou-P(10 μmol.L-1)at 37 ℃ for 30 min;(c)Stained cells further exposed to 200 μmol.L-1Cu(NO3)2solution at 37 ℃ for 300 min

3 Conclusions

In summary,we successfully developed a new reaction fluorescent probe for detecting Cu2+.Probe Cou-P exhibits a fluorescence "turn-on"recognition process for Cu2+.The recognition mechanism of probe Cou-P for Cu2+was investigated by UV-Vis,fluorescence and ESI-MS spectrometry.In application,Cou-P shows low cytotoxicity and good membrane permeability.More importantly,Cou-P was successfully used for the detection of Cu2+in living cells,indicating its great potential for Cu2+detection in biological science.

Supporting information is available at http://www.wjhxxb.cn

猜你喜歡
南京
南京比鄰
“南京不會忘記”
環球時報(2022-08-16)2022-08-16 15:13:53
南京大闖關
江蘇南京卷
學生天地(2020年31期)2020-06-01 02:32:22
南京·九間堂
金色年華(2017年8期)2017-06-21 09:35:27
南京·鴻信云深處
金色年華(2017年7期)2017-06-21 09:27:54
南京院子
電影(2017年1期)2017-06-15 16:28:04
又是磷復會 又在大南京
南京:誠實書店開張
南京、南京
連環畫報(2015年8期)2015-12-04 11:29:31
主站蜘蛛池模板: 91日本在线观看亚洲精品| 国产精品va| 亚洲自偷自拍另类小说| 99热这里只有精品在线观看| 99re经典视频在线| 亚洲免费毛片| 欧美精品高清| 亚洲区第一页| 国产免费a级片| 亚洲国产午夜精华无码福利| 蜜臀AV在线播放| 亚洲人网站| 午夜a视频| 色综合国产| 99这里只有精品在线| 黄色成年视频| 久久久久人妻一区精品| 亚洲最大情网站在线观看| 毛片免费高清免费| 日本人妻一区二区三区不卡影院| 欧美在线中文字幕| 一本大道无码高清| 国产成人一区二区| 成人亚洲天堂| 免费a级毛片18以上观看精品| 伊人久热这里只有精品视频99| 动漫精品啪啪一区二区三区| 久久 午夜福利 张柏芝| 国产毛片高清一级国语| 福利姬国产精品一区在线| 91福利国产成人精品导航| 亚洲欧洲天堂色AV| 亚洲精品自拍区在线观看| 99久久精品免费观看国产| 在线另类稀缺国产呦| 欧美人在线一区二区三区| 国产精品视频导航| 久久一色本道亚洲| 国产精品精品视频| 亚洲 欧美 偷自乱 图片| 91偷拍一区| 麻豆精选在线| 日韩精品毛片人妻AV不卡| 欧美日本激情| 欧美亚洲日韩不卡在线在线观看| 一本大道无码高清| 九九久久99精品| 一级成人欧美一区在线观看| 草草线在成年免费视频2| 美女内射视频WWW网站午夜| 久久五月视频| 国产熟女一级毛片| 国内丰满少妇猛烈精品播| 福利在线不卡| 日韩小视频网站hq| 免费在线色| 中文天堂在线视频| 中文字幕永久视频| 国产尤物jk自慰制服喷水| 国产精品久久久免费视频| 国产靠逼视频| 超碰精品无码一区二区| AⅤ色综合久久天堂AV色综合| 亚洲AV无码乱码在线观看裸奔 | 麻豆精品在线| 夜夜操国产| 国产00高中生在线播放| 亚洲第一黄片大全| 亚洲精品在线91| 国产麻豆福利av在线播放| 亚洲天天更新| 99视频在线免费观看| 日本成人精品视频| 麻豆精品视频在线原创| 亚洲熟女中文字幕男人总站| 国产精品网址你懂的| 国产成人乱无码视频| 免费亚洲成人| 亚洲成人在线免费| 国产亚洲精| 国产精品福利社| 亚洲人成在线免费观看|