999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

Signal-recycled weak measurement for ultrasensitive velocity estimation?

2021-06-26 03:29:16SenZhiFang方森智YangDai戴陽QianWenJiang姜倩文HuaTangTan譚華堂GaoXiangLi李高翔andQingLinWu吳青林
Chinese Physics B 2021年6期

Sen-Zhi Fang(方森智), Yang Dai(戴陽), Qian-Wen Jiang(姜倩文),Hua-Tang Tan(譚華堂), Gao-Xiang Li(李高翔), and Qing-Lin Wu(吳青林)

Department of Physics,Central China Normal University,Wuhan 430079,China

Keywords: quantum optics,weak value,recycling

1. Introduction

Weak value amplification, which was originally introduced by Aharonov, Albert, and Vaidman in 1988,[1]has shown its outstanding performance in precise measurements.By preparing appropriate pre-and post-selected states of a system,one can obtain a significantly amplifying signal in meter distribution. It has been successfully used to achieve many sensitive physical effects,such as beam deflections,[2,3]phase shift,[4–7]spin Hall effect of light,[8]ultralow velocity,[10,11]angular rotations,[12–14]and temperature measurements.[15–17]In this article,we focus on the weak value amplification setup used in Ref.[10],which couples the velocity of a piezo-driven mirror to the“which-path”modes of a Michelson interferometer. The meter corresponds to the arrival time of output light from the dark port of the interferometer.

The common disadvantage of standard weak-value-based metrology is that only a small part of information of the incident beam is used, while most information is lost during the post-selection process. Therefore, this technique is also thought as a method that concentrates finite Fisher information of measured parameters on a fraction of events.[18–20]There is plenty of doubt whether the weak value amplification can increase the ultimate limit of measurement precision.[18,21,22]With regard to probe loss by post selection, researchers have put forward the power recycling technique, which is initially applied in the detection of gravitational waves.[23,24]The aim is to reuse the discarded events by placing a partially transmitting mirror at the bright port of interferometer. This has also been demonstrated and can be used to effectively improve the ultimate signal-to-noise ratio of beam deflections in both theory and experiment.[25–27]Here we propose a signal recycling scheme, which places a partially transmitting mirror at the dark port of an interferometer,to overcome the shortcoming of post-selection.

2. Interferometric weak value measurement

We have already known from Ref.[10](see Fig.1,in the absence of partially transmitting mirrorMp) that light entering into the Michelson interferometer is a non-Fourier limited Gaussian pulse,

where we have assumedkvτ ?φ ?1,Nis the normalized average photon numbers per unit time,τis the modulated pulse width,vis the velocity of moving mirror,φis the near destructive interferometric angle, andk=2π/λis the wave number of laser.

whereNdet=Nφ2is the number of detected photons.

Fig. 1. Schematic of weak-value velocity measurement with signal recycling technique. The beam is modulated as a Gaussian shaped pulse by an AOM(acoustic optical modulator)and then enters into the Michelson interferometer,which is turned slightly off destructive interference by a small angle 2φ. The piezo-drven mirror (PM) is moving with a low velocity v, which is hopeful for precise measurement. The majority of light would be reflected back and a small amount is collected by thephoto detector(PD),and the arrival time of light is measured with a time-resolved measurement module. We note the orientations of reflected and detected light as bright and dark port of the interferometer,respectively. In the presence of the partially transmitting mirror Mp,the light at the dark port would be reflected and cycled.

3. Signal recycling

In our signal recycling scheme, we form a resonant cavity by introducing a partially transmitting mirror. Unlike the power recycling weak value scheme[25–27,31]in which the partially transmitting mirror is at the bright port,here we place the mirror at the dark port of the Michelson interferometer,i.e.,in front of the detector. We will show that this cavity in our signal recycling scheme can also improve the number of detected photons and the corresponding SNR like the power recycling scheme.

Fig. 2. Schematic of a resonant optical cavity formed by two partially transmitting mirrors. Under the condition of the resonant cavity, the reflected amplitude Er is exactly zero and the amplitude leaving the cavity through the second mirror Eout becomes equal to the input amplitude E0.

and the amplitude of light reflected back the laser is the sum of light reflected by the first mirror and reflections inside the cavity

We note that the amplitude of outgoing light from the cavity is

Under the condition of resonant cavity,the phase addition every cycle isθ=2πn,wherenis an integer. Thus we find the amplitude of reflected light is zero and the outgoing light is equal to the initial incident light. The light in the cavity has a gain where we have made a series expansion of

and abandoned higher orders under the conditionkvτ ?φ ?1 andcτ ?lλ >2nmaxlcav. The parameterφ1is

Thus the steady state amplitude of detected light is

We are interested in the time shiftδt2where the velocity is included, andδt3is a constant time delay which does not influence our measurement. Thus the intensity of detected light is

4. Comparison with standard weak measurement

We now compare these results with standard weak measurement. From Eq.(17)we can easily obtain the number of detected photons and the signal-to-noise ratio of velocity in this signal-recycled scheme

If the loss of system is also considered in the standard scheme,we can have the factors about improvements of detected photons and SNR as follows:

which indicate that we cannot simultaneously reach the optimal improvements of detected photons and information about the velocity. Equation(21)can be written as

Fig.3. The parameters G(red,solid)and Q(blue,dashed)versus φ,γ and r:(a)φ is between 0.1 and 0.3,and r=0.9,γ=0.2;(b)γ is between 0 and 0.4,and r=0.9,φ =0.2;(c)r is between 0 and 1,and φ =0.2,γ =0.2.

The coefficient

which means that the time shiftδt2in the signal-recycled scheme is smaller than that in the standard weak value measurement. This is owing to the walk-off effect because the time shift of a small fraction of light exiting to the dark port is forward or backward, which causes a complementary shift in the opposing direction for the light exiting to the bright port.We now simply explain this effect.

Fig. 4. Walk-off effect in the signal-recycled scheme: (a) f(t) (red,solid), fT(t) (blue, dashed) and fR(t) (black, dotted); (b) n=0 (red,solid),n=1(blue,dashed),n=2(black,dotted),n=3(purple,dashdotted).

5. Comparison with power recycling weak measurement

We now compare the signal recycling scheme with the power recycling scheme.[31]Since the detected light in the signal recycling scheme is the same as that in the power recycling scheme,we now focus the light reflected back to the laser and in the cavity. It is easy to calculate the reflected light in the signal recycling scheme as follows:

and the reflected light in the power recycling scheme is

in the signal recycling and power recycling schemes. Similarly,the amplitudes of light in the cavity are,respectively,

in the signal recycling and power recycling schemes.

When the reflectivity of the partially transmitting mirror isr=rG,i.e.,the intensity of detected light reaches the maximum,we can obtainYrp=0 andYrs>0.We plotYrs,Ycs,Ycpin Fig.5 forr=rGunder some conditions. When the reflectivity of the partially transmitting mirror isr=rQ,i.e.,the signal-tonoise ratio of detected light is maximal,we showYrs,Yrp,Ycs,Ycpin Fig.6 under some conditions. It is easy to see that the intensity of the reflected light is stronger and the light in the cavity is weaker in the signal recycling scheme than those in the power recycling scheme.

Now we consider the reflected light as the cavity locking signal like Ref.[32],where the Pound–Drever–Hall technique plays a critical role.[33–35]Thus we need not place a beam splitter at the detecting port like Ref.[27]and the collectiondetection efficiency can be improved. Equations(24)–(27)are an approximation for a Gaussian pulse but exactly accurate for a stable wave. Here we directly use the Pound–Drever–Hall analysis in the supplemental material of Ref. [27]. If a reference beam with a phase modulation by the angular frequency of?is used to control the cavity length, then the reflected light is

Fig. 5. Reflectivity of the partially transmitting mirror, r = rG =: (a) Yrs (red solid), Ycs (black dotted), Ycp (purple dashdotted)versus φ for γ =0.2; (b)Yrs (red solid),Ycs (black dotted),Ycp(purple dash-dotted)versus γ for φ =0.2.

Fig.6.Reflectivityofthepartiallytransmittingmirror,r=rQ=(a)Yrs(redsolid),Yrp(bluedashed),Ycs(blackdotted),Ycp(purple dash-dotted)versus φ for γ =0.2;(b)Yrs (red solid),Yrp (blue dashed),Ycs (black dotted),Ycp (purple dash-dotted)versus γ for φ =0.2.

whereais a constant,E0is the amplitude of laser,ω0is the angular frequency of the laser,αis the modulation depth,andg(ω)is denoted as

Fig.7. The error signal Sr (blue dashed)and St (red solid), in units of wavelength λ in the horizontal axis: (a) the power recycling scheme,(b)the signal recycling scheme.

while the error signal from the detected light is

6. Conclusions

We have proposed a signal-recycled technique to increase the intensity of the outgoing light of the standard-weak-valuebased velocity measurement system. Like the power-recycled scheme, the cavity formed by the Michelson interferometer and the partially transmitting mirror can increase the SNR of velocity estimation compared to the standard weak measurement. However, optimal improvements of detected photons and SNR cannot be obtained simultaneously owing to the walk effect.Moreover,we find that the reflected light is stronger and the light in cavity is weaker compared with those in the power recycling scheme,which may increase the collection-detection efficiency in prospective relevant experiment.

主站蜘蛛池模板: 无码网站免费观看| 免费一级无码在线网站| 国产综合欧美| 欧美精品高清| 欧美精品在线视频观看| 99ri精品视频在线观看播放| 都市激情亚洲综合久久| 亚洲综合极品香蕉久久网| 国产日韩精品欧美一区灰| 国产xxxxx免费视频| 亚洲欧美另类久久久精品播放的| 中文国产成人精品久久| 国产美女无遮挡免费视频| 日本精品影院| 99在线观看精品视频| 亚洲第一区欧美国产综合 | 狠狠色香婷婷久久亚洲精品| 欧美一级片在线| 国产黄色片在线看| 亚洲最黄视频| 99久久国产自偷自偷免费一区| h网站在线播放| 久久综合伊人 六十路| 成年人福利视频| 天天色天天综合网| 97se亚洲综合在线天天| 精品无码一区二区三区在线视频| 亚洲第一天堂无码专区| 亚洲成肉网| 久久人妻系列无码一区| 国产99精品视频| 中文无码精品A∨在线观看不卡| 亚洲日韩每日更新| 国产无遮挡猛进猛出免费软件| 国产呦精品一区二区三区网站| 色偷偷av男人的天堂不卡| 欧美啪啪网| 麻豆国产精品一二三在线观看| 欧美人与动牲交a欧美精品| 欧美亚洲国产精品第一页| 日本国产在线| 欧美全免费aaaaaa特黄在线| 丝袜国产一区| 欧美成人午夜在线全部免费| 丁香五月婷婷激情基地| 国产激情无码一区二区三区免费| 国产视频一二三区| 色综合五月婷婷| 久久精品这里只有精99品| 亚洲人成亚洲精品| 99精品这里只有精品高清视频| 日本成人精品视频| 91精品国产自产在线观看| 91系列在线观看| 日韩欧美国产中文| 国产不卡一级毛片视频| 久久久精品久久久久三级| 国产乱人伦偷精品视频AAA| 99视频在线免费看| 99精品影院| 国产一区二区福利| 91在线视频福利| 久久久久中文字幕精品视频| 欧美在线三级| 91热爆在线| 青青草一区| 免费Aⅴ片在线观看蜜芽Tⅴ| 精品久久久久久中文字幕女| 波多野结衣无码视频在线观看| 精品亚洲麻豆1区2区3区| 熟妇无码人妻| 国产伦精品一区二区三区视频优播 | 亚洲精品777| 丝袜久久剧情精品国产| 亚洲精品亚洲人成在线| 露脸真实国语乱在线观看| 国产亚卅精品无码| 国产精品va| 国产免费高清无需播放器| 免费观看无遮挡www的小视频| 国产又爽又黄无遮挡免费观看| 高清久久精品亚洲日韩Av|