摘 要:隨著三網融合的逐步深入,廣電網絡的業務承載能力應不斷加強,開展互動、寬帶和集客專網等服務,必須重新構建使用具備完善的保護和管理手段的主流技術,來滿足干線層大顆粒業務的需求。
關鍵詞:網絡拓撲的設計;波道和容量的確定;承載的業務;設備運行的環境
At the beginning of the planning and construction of the Zaozhuang trunk transmission network
口Li Xiugang Fang Hua
(Zaozhuang radio and TV station ,Shandong Zaozhuang 277102, China . Zaozhuang Cable Radio and Television Information Center, Shandong Zaozhuang 277102, China .)
Abstract: With the integration of three networks gradually thorough, carrying radio and television network business ability should continue to strengthen, to carry out interactive, broadband and set off the network services, must be re constructed using the mainstream technology has perfect protection and management tools, to meet the needs of business route layer of large particles.
Key words: The network topology design; To determine the channel and capacity;
Bearing business; Equipment operation environment.
隨著互動電視、寬帶和專線等業務的開展,網絡帶寬的需求不斷提升,擬建設一套安全可靠、維護簡便、平滑演進的傳送網絡,需基于以下幾點考慮:
一、網絡路由的建設。根據棗莊的行政區劃和人口分布的特點,組網架構為南、北環型。其中,南環設有高新、薛城、臺兒莊和嶧城四個節點;北環設有山亭和滕州兩個節點,光纜鏈路的衰耗值應滿足0.275dB/KM最差設計衰耗(如圖1所示)。
二、容量說明。擬采用OTN設備建設1套40×10Gbps DWDM(波分復用)單纖單向系統,初期每個節點配置1個波,將來根據業務需要再擴波。
三、業務開通。以棗莊為中心到每個節點都可以開通業務,承載雙向增值業務,從以傳統的視音頻業務,逐步過渡到數字電視直播頻道、時移、VOD點播、高清頻道、寬帶上網、智慧城市建設和大客戶專網等服務,構建冗余或保護波道,快速實現業務開通與保護倒換,各節點之間業務互通需要經過棗莊中心為轉接點。
四、設備運行環境要求。
1、機房內按國標GB2887-89《計算機場地安全要求》的規定配置空調設備,要求為:
2、設備工作直流電源要求輸入電壓:-48V-15%+20%DC,正極接地,模塊化設計,進行1+1備份。
3、設備接地要符合國標YD5098-2005接地阻值要求:交流工作地R不大于4歐姆,安全保護地R不大于4歐姆;防雷保護地R不大于10歐姆,直流工作地R不大于4歐姆,每個接地端子不得連接超過2個對象。
五、設備選型。
1、通過技術論證,本工程擬采用阿朗公司提供的1830PSS 32作為市局設備,1830PSS 4作為區局設備。
設備硬件平臺規格信息(單機框尺寸):
2、對機架和機盤的一般要求
我們采用2200mm x 600mm x 300mm機架,與其它機架高度一致,整齊美觀,預留充足的設備安裝位置和上下各1U的通風空間。
六、總結
目前,我國已經基本具備三網融合的技術條件、網絡基礎和市場空間。三網融合后,廣電不僅可以延伸自身的產業鏈,而且可以降低成本,擴大用戶群,從而促進產業的發展,同時帶動相關產業鏈,推動我國經濟的快速發展。
作者簡介 : 房華 1971年 男,高級工程師 ,廣播電視技術
李修剛 1967年 男 工程師, 電視無線發射