摘要:都江堰互通主線橋梁第17聯現澆梁體采用盤扣式滿堂支架法施工,因盤扣式腳手架具有節約支架材料、降低造價、節約成本、安全性能好等優點。本文介紹了都江堰互通主線橋梁第17聯現澆梁體盤扣式滿堂支架的設計以及支架主要結構的檢算,對同類型橋梁的施工具有一定的指導作用。
Abstract: The 17th joint cast-in-situ beam of the Dujiangyan Interchange Main Line Bridge is constructed by the button-type full-frame method. The button-type scaffolding has the advantages of saving the bracket material, reducing the cost, saving cost and good safety performance. This paper introduces the design of the 17th joint cast-in-situ beam-type full-frame bracket of the Dujiangyan Interchange Main Line Bridge and the check of the main structure of the main frame, which has a certain guiding effect on the construction of the same type of bridge.
關鍵詞:盤扣式;滿堂支架;支撐體系;受力驗算
Key words: button type;full hall bracket;support system;force check
中圖分類號:U445.3? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 文獻標識碼:A? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? 文章編號:1006-4311(2019)17-0138-04
1? 工程概況
都江堰互通主線橋梁位于G0511線德陽至都江堰高速公路工程第十合同段,其第17聯現澆梁體采用單箱五室預應力砼直腹板等截面連續梁。箱梁寬17.348-30.655m(斜長),箱梁高度200cm,腹板厚度40cm,底板厚度25cm,頂板厚度25cm,橫隔板厚30cm,翼板寬度175cm。中跨梁體支點處2.66米范圍內為實心段梁體,作為隱形蓋梁。箱梁澆筑采用C50混凝土。
2? 支架設計方案
支架總體按以下原則布置:
標準層豎向步距1.5m,頂層步距最大為1m;支點橫梁處間距為0.9米(縱向)或0.6米(縱向);空箱處間距為1.2米(縱向)×1.5米(橫向);腹板處間距為1.2米(縱向)×1.2米(橫向);橫梁處間距為0.6米(縱向)×1.2米(橫向);底模采用15mm竹膠板,次龍骨采用10cm×10cm方木,主龍骨采用雙肢槽鋼進行整體拼接成結構形狀;翼板采用雙鋼管。詳見圖1、圖2所示。
3? 盤口式支架的設計取值
3.1 支架結構材料物理力學性能
5? 結語
本文結合了都江堰互通主線橋梁第17聯現澆梁體對盤扣式滿堂支架設計及檢算進行了淺析。對盤扣式滿堂支架設計支架的設計及檢算有一定的借鑒作用。
參考文獻:
[1]中華人民共和國住房和城鄉建設部,建筑施工承插型盤扣式鋼管支架安全技術規程[M].北京:中國建筑工業出版社,2010.
[2]中國鐵路總公司.高速鐵路橋涵工程施工技術指南[M].北京:中國鐵道出版社,2010.
[3]周水興等編著.路橋施工計算手冊[M].人民交通出版社,2001.
[4]鋼結構工程施工質量驗收規范[M].中國計劃出版社,中華人民共和國建設部主編,2002.
作者簡介:羅衡(1984-),男,湖南人,本科,研究方向為施工技術。