劉朝紅 鄧建 鄒顏矯


【摘要】目的 研究臨床醫學檢驗中控制血液細胞檢驗質量的方法。方法 回顧性分析90例血液細胞檢驗患者其檢驗結果,找到影響檢驗質量的因素。結果 不同稀釋比例、血液標本放置時間下血液標本檢驗結果數據值相差較大(P<0.05)。結論 抗凝劑配置比例、血液樣本放置時間均對血液細胞檢驗質量有影響,需把控各環節來保證檢驗結果準確度。
【關鍵詞】醫學檢驗;血液細胞;檢驗質量
【Abstract】Objective To study the method of controlling the quality of blood cell test in clinical medicine.Methods The results of 90 blood cell test patients were analyzed retrospectively,and the factors influencing the test quality were found.Results :Under different dilution ratio and time of blood sample placement,the data of blood sample test were significantly different(P<0.05).Conclusion The proportion of anticoagulant and the time of blood sample placement have an impact on the quality of blood cell test.It is necessary to control each link to ensure the accuracy of test results.
【Key words】Medical examination;Blood cells;Examination quality
通過臨床醫學檢驗中血液細胞檢驗,能為疾病的臨床診斷提供重要信息,但這是在保證檢驗結果準確度的前提下得以實現的。實際臨床檢驗時,會有諸多因素影響到血液結果,只有把控這些因素,才能提高檢驗準確度。因此,本研究主要就對不同抗凝劑配置、不同室溫存儲時間對檢驗結果的影響作出分析,依此提出質量控制方法。
1 資料與方法
1.1 一般資料
以2018年5月~2019年5月在我院體檢、自愿參與實驗的90名對象為例,其中男47例、女43例,年齡最大值55歲、最小值18歲,平均值37.2±2.5歲。
1.2 方法
取受試者靜脈血液,分別按兩種稀釋比進行稀釋:1:10000和1:5000,相應平分成90份待檢。另外儲存質量方面,在22℃室溫下,于30 min內檢測其中30份血液標本;3 h后檢測另外30份血液標本;6 h后檢測最后30份血液標本[1]。
1.3 研究指標
①分析不同稀釋比例對血液細胞檢驗結果的影響。②分析室溫下不同檢驗時間對結果的影響。
1.4 統計數據檢驗
所得檢驗結果數據以(x±s)的方式表示,采用t檢驗;由SPSS 22.0醫學軟件做統計分析。有統計學意義的檢驗判定:P<0.05。
2 結 果
2.1 不同稀釋比例所得血液細胞檢驗結果
兩種不同稀釋比例下的血液標本檢驗結果數據值相差較大(P<0.05)。見表1。
2.2 室溫下不同放置時間血液標本檢驗結果
隨著血液標本放置時間的延長、檢驗結果出現較大差異(P<0.05)。見表2。
3 討 論
稀釋是對血液細胞當中白細胞數量計算的重要操作步驟,標準的抗凝劑配置比例是1:10000,應嚴格按照這一比例進行配置,以免由于稀釋比例過低而發生細胞重合缺損、影響到檢驗結果。
血液標本檢測時,注意嚴格把控標本放置時間,因放置時間會對血液細胞檢驗質量造成嚴重影響,因此應避免樣本被放置時間延長而造成血液細胞形態發生變化,控制在30分鐘內完成檢驗[2]。
總之,抗凝血劑配置比例、血液樣本放置時間皆會影響到血液細胞標本檢驗質量,應嚴格把控檢驗工作中的每一個環節,從根本上控制檢驗質量,保證血液細胞檢驗結果的科學性、準確性。
參考文獻
[1] 王朝輝.臨床醫學檢驗中血液細胞檢驗質量控制的對策分析[J].首都食品與醫藥,2019,26(23):124-125.
[2] 張宇杰.在臨床醫學檢驗中進行血液細胞檢驗質量控制的效果觀察[J].中國社區醫師,2019,35(31):122,124.