999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

可轉換型下腔靜脈濾器的應用

2020-07-27 09:17:21楊州趙渝
醫學信息 2020年12期
關鍵詞:并發癥

楊州 趙渝

摘要:置入可轉換型下腔靜脈濾器(CF)是預防下肢深靜脈血栓形成(DVT)患者發生肺動脈栓塞(PE)的有效措施之一。盡管CF已廣泛應用于臨床,但在使用過程中的適應證、轉換指證、并發癥的處理等尚無明確的指南或專家共識。本文就CF的應用現狀、產品特性、適應證、濾器轉換、并發癥及處理作一綜述,旨在為臨床醫生使用CF提供參考。

關鍵詞:可轉換型下腔靜脈濾器;深靜脈血栓形成;肺栓塞;濾器轉換;并發癥

Abstract:The placement of a convertible inferior vena cava filter (CF) is one of the effective measures to prevent pulmonary embolism (PE) in patients with deep vein thrombosis (DVT) of the lower extremities. Although CF has been widely used in clinics, there are no clear guidelines or expert consensus on the indications, conversion indications, and management of complications during use. This article reviews the application status, product characteristics, indications, filter conversion, complications and treatment of CF, and aims to provide a reference for clinicians to use CF.

Key words:Convertible inferior vena cava filter;Deep vein thrombosis;Pulmonary embolism;Filter conversion;Complications

靜脈血栓栓塞癥(venous thromboembolism,VTE)包括深靜脈血栓形成(DVT)和肺栓塞(PE)。急性肺栓塞是一種高致死率、高誤診率的疾病,因其發病隱匿且癥狀無特異性,常常被忽視,是住院患者非預期死亡和圍手術期死亡的重要原因,同時也是最可預防的死亡原因[1,2]。據報道[3],在美國,肺栓塞每年導致10~20萬人死亡;而我國PE的發病率也呈逐年上升趨勢[4]。下肢DVT是導致肺栓塞的最主要原因,對于存在抗凝治療禁忌或發生抗凝并發癥者,經皮置入下腔靜脈濾器(IVCF)可以有效預防致死性PE的發生。自1967年推出的Mobin-Uddin傘形濾器系統起,濾器不斷改進,IVCF的有效性和安全性大大提高,顯著降低了致死性PE發生率。目前IVCF主要分為永久型、臨時型、可回收型及可轉換型濾器。可轉換型腔靜脈濾器(CF)作為可選擇型濾器的一種,其從2010年開始應用于臨床,于2012年進入國內市場,能有效預防深靜脈血栓脫落所致的PE。同時CF能在肺栓塞高風險期不確定的情況下,置入下腔靜脈后,經過較長時間后完成濾器的轉換,減小濾器對腔靜脈血流的影響。CF的置入、轉換操作簡便安全,目前已被廣泛應用于血管腔內治療。本文就CF的產品特性、應用現狀、適應證與禁忌證、濾器置入后轉換、并發癥及處理作一綜述。

1 CF的產品特性

CF(VenaTech? ConvertibleTM Vena Cava Filter)是為預防下腔靜脈系統血栓脫落引起肺動脈栓塞而設計的一種裝置。VTCF和VenaTech LP腔靜脈濾器使用的是相同材料,是由鈷鉻金屬合金制成,于2010年投入臨床使用。VTCF輸送器的外徑是12.9 F,可經頸靜脈或股靜脈途徑置入,適宜放置的下腔靜脈(IVC)最大直徑為28 mm,由穩定支腳、過濾支腳、鎖定裝置(保持帽)和掛鉤組成,8個穩定支腳上均有相反的錨定鉤,此設計減少了向任何方向的移動,并且將濾器的頭端固定在腔靜脈中心;且濾器與IVC壁的接觸均勻分布,沒有單一的接觸點或應力點,降低了IVC穿孔的風險。過濾支腳的頂端被固定在一個可移除的鎖定裝置內,當患者的肺栓塞風險消失、無需濾器攔截血栓時,可通過經頸靜脈將可轉換濾器轉換成一個開放的結構[5],這也是VTCF的獨特專利概念。此款濾器因其攔截功能可轉換的特性,為有暫時或永久肺栓塞風險的患者提供了安全和有效的保護。

2 CF的應用現狀

在腔內治療及血管外科領域,下腔靜脈濾器使用越來越多,適應證也越發廣泛。有研究對美國2000~2009年全國住院患者進行回顧性橫斷面研究[6],結果表明放置IVC濾器的數量在過去10年中增加了234%(由2000年的56380個增加到2009年的132049個)。另有研究表明[7],2005~2010年下腔靜脈濾器的使用數量逐年增加(2005年為100434人,2010年為129614人,增長率為5.81%),從IVCF的置入數量看,總體上呈增加趨勢,其使用量增加與VTE發病率升高和臨床診斷能力的提升有關;從IVCF置入的適應證看,相對于預防性適應證,有靜脈血栓栓塞治療指征的置入比例顯著增加(2005年的69.8%增至2014年的80.4%),其主要原因是2010年FDA強調了濾器留置后相關并發癥的風險。

CF作為可選擇性濾器的一種,臨床上的適應證同可回收型濾器。美國11個醫療中心2015年完成了對CF臨床應用研究[8],共納入149例患者,CF植入后僅發生1例癥狀性PE,其攔截血栓的有效性得以證實。有研究報道[8,9],CF的首次轉換率為64.4%~96.7%,轉換成功率為92.7%~96.8%,置入到轉換的平均時間為16~130.7 d,表明CF在臨床使用過程中具有較高的轉換率和轉換成功率,相對于臨床上的可回收型濾器和臨時濾器而言,CF從置入到轉換的時間窗更長,并且CF的轉換特性不會隨著時間的延長發生改變。同時CF由于不存在回收失敗的問題,在腔靜脈遠期通暢率上可能更有優勢。

3 CF置入的適應證和禁忌證

雖然IVCF置入下腔靜脈預防肺栓塞的效果確切,但目前國內外對于濾器類別的選擇尚無統一的標準[10,11]。IVCF可留置于上腔靜脈或下腔靜脈,其中下腔靜脈濾器置人術最常見,下腔靜脈的腎下段是IVCF置入的常規位置。2019年7月,中華醫學會外科學分會血管外科學組發布了最新的IVCF臨床應用指南[12],但目前尚無規范使用CF的指南或專家共識,暫將可轉換型、可回收型及臨時型濾器歸為可選擇型濾器。對于CF的放置,需嚴格掌握手術適應證,以避免器材的過度使用。

3.1適應證? 在滿足有置入可選擇性濾器的條件下,需達到以下5種要求[12-14]:①患者無植入永久性濾器的指證;②臨床評估PE發生率為高風險;③VTE復發為低風險;④患者植入濾器可以被安全轉換;⑤患者同意轉換濾器。

3.2禁忌證? CF同其他濾器一樣,置入術前需排除以下5種情況:①腔靜脈異常解剖無濾器植入位置;②腔靜脈內充滿血栓;③腔靜脈無入路;④腔靜脈慢性閉塞;⑤菌血癥、無法糾正的凝血功能異常。但同時還要注意下腔靜脈的直徑須小于28 mm[15]。

4 CF的轉換問題

當患者的肺栓塞風險消失、無需濾器攔截血栓時,可通過經頸靜脈途徑將濾器轉換成一個開放的結構。通常IVCF植入后,會對IVC壁造成一定的損傷,濾器金屬支撐桿會被增生的內膜包埋,這也是濾器取出困難的原因之一[16,17]。CF與其他類型濾器不同的是:CF不需要取出,繼而避免了因內膜增生造成濾器取出失敗,甚至損傷IVC壁的風險。因CF的濾器鎖扣在設計上位于腔靜脈中心,一般不與IVC壁接觸,其轉換時間理論上不受置人時間限制。有報道稱[8],最長有在置入后的391 d完成了成功轉換的病例。

4.1 CF轉換指證? ①通過臨床癥狀、靜脈超聲、CT、靜脈造影等方式綜合評估,DVT處于穩定狀態或已消失,D-Dimer在15 d內2次檢查正常;②患者由于得到適當持續的基本處置(治療或預防),或有臨床意義的PE風險降到可接受程度;③預計患者不會因臨床情況變化、基本治療中斷、或臨床治療調整而恢復PE高風險狀態;④患者年輕或預期壽命足夠長,可以從濾器的轉換中獲益(可選擇性濾器在體內長期存在,發生并發癥的風險會升高[18]);⑤經過各種檢查與評估,CF可以被安全地轉換;⑥患者或監護人知情并同意濾器的轉換。

4.2影響濾器轉換的因素? 可轉換性是CF的重要特性,若不進行濾器的轉換,CF將作為永久型濾器長期留置在患者的下腔靜脈內。濾器相關并發癥會伴隨濾器植入時間的延長而逐漸增多,如濾器傾斜、移位、折斷、濾器支腳穿透IVC壁、下腔靜脈阻塞等[19]。美國FDA曾發布公告,要求臨床醫師在確保安全的前提下盡早回收或轉換濾器,以避免由于長期留置帶來的并發癥。從設計原理上看,CF過濾支腳的展開后,濾器對下腔靜脈的血流動力血影響會大大減少[20],但目前尚無針對可轉換濾器轉換后長期安全性的研究。Hohenwalter EJ等[8]通過多中心研究發現,CF的嘗試轉換率高達64.4%,轉換成功率為92.7%。結合上述臨床研究結果和大量可回收型濾器的隨訪數據,可轉換型濾器未能轉換首要原因是失訪[21,22],其他因素包括患者依從性差、高齡、合并惡性腫瘤、身體狀態較差、預計生存時間短以及社會經濟因素等[23-25]。

5 CF的并發癥及處理措施

5.1濾器移位? 濾器從置入后的位置向上或向下移動距離超過2 cm即稱為濾器移位[26,27]。造成濾器的移位的原因繁多,向頭側移位較多見。有研究報道了1例可轉換型濾器置入下腔靜脈后,濾器支腳不打開并移位至右心室,術者立即使用鵝頸抓捕器,配合16 F的大鞘,通過頸靜脈途徑安全取出[28]。根據濾器移位的位置不同,可導致不同的后果,較嚴重的情況有影響腎靜脈血流、移位至心臟導致心律失常、心室壁穿孔等[29],均需要立即干預,首選血管腔內微創手術,可使用鵝頸抓捕器或三葉草圈套器,聯合導絲、導管、球囊等取出濾器;但在特殊情況下,如患者已發生靜脈的破裂出血,或者通過介入微創的方式不能取出,可行開放手術或腹腔鏡下取出濾器[30,31]。

5.2濾器傾斜與轉換失敗? 濾器傾斜通常定義為濾器的中心長軸與下腔靜脈縱軸之間的夾角大于15°。造成濾器傾斜的原因主要有濾器本身結構問題、傘型設計的濾器發生傾斜的比例較其他濾器高[11]、濾器置入過程中的操作不當、下腔靜脈解剖結構異常以及植入術入路的選擇。濾器發生傾斜后可能導致血栓攔截作用下降、肺栓塞發生,IVC穿孔等后果。目前對于可轉換型濾器而言,濾器的傾斜可能導致濾器鎖定裝置和掛鉤貼向下腔靜脈壁,會導致轉換困難、甚至轉換失敗。美國多中心研究統計98例患者中有3例患者因濾器鎖定裝置貼壁嚴重,導致了轉換失敗[8]。可轉換濾器傾斜后大多無癥狀,一般予以臨床觀察,無需特殊處理,但可轉換型濾器一旦轉換失敗即轉化為永久型濾器,相應的長期并發癥可能增加及抗凝藥物的使用時間延長。

5.3濾器斷裂? 在臨床上濾器斷裂極少見,目前暫無可轉換型濾器斷裂并導致相關后果的報道。若濾器折斷部分無移動且患者無臨床癥狀,可在規范抗凝治療下密切隨訪[32],必要時通過介入手術或外科手術取出。

5.4腔靜脈穿孔? 當IVCF的錨定支腳或支撐桿突出IVC壁超過3 mm,可認定為濾器導致IVC穿孔。濾器傾斜、斷裂、濾器的外擴張力過強、腹主動脈搏動或下腔靜脈直徑較小等因素[33]可造成IVC壁慢性穿孔。由于可轉換型濾器的8個支腳與下腔靜脈為線性接觸,非點接觸,故其發生比率較低。多角度的X光下腔靜脈造影或高分辨率CT可完成IVC穿孔的評估,Hohenwalter EJ等[8]在一項多中心臨床試驗中對92例患者置入CF半年后行腹部CT檢查,均未見CF濾器植入后腔靜脈發生穿孔。IVC穿孔多數情況下不會導致嚴重并發癥,當濾器支腳穿透腹主動脈、腎血管、腸管壁或發生腹膜后出血時,須行介入微創取出,或予以開放手術治療,目前已有報道通過直接開腹打開靜脈取出、或通過腹膜后入路取出濾器并修補腔靜脈[34,35]。

5.5下腔靜脈阻塞? IVCF攔截大量血栓或IVC血栓形成,并引起下腔靜脈系統血液回流受阻,表現出布加綜合征相似的臨床癥狀,即為濾器導致的下腔靜脈阻塞。一旦明確診斷,若患者無抗凝禁忌證,應加強抗凝治療。若有明顯臨床癥狀者,可采用導管吸栓、CDT、PMT等方法清除血栓;若濾器內血栓較多或血栓已蔓延至濾器上方,須在臨時型或可回收型濾器保護下進行以上治療[36]。若IVCF內血栓已機化、牢固粘連,導致濾器位置嚴重狹窄或閉塞時,可按IVC阻塞綜合征處理[12]。

5.6發生PE? IVCF植入后,濾器頂部血栓脫落、急性IVC阻塞會導致癥狀性或大面積PE。另外濾器傾斜后攔截效果下降也是濾器植入后發生PE的一個重要原因[12]。美國多中心對于可轉換濾器的研究中發現,CF置入后發生PE的風險為0.8%[8];李津凱等[9]研究發現,CF植入后有1例(1/31,3.2%)患者發生癥狀性PE。對于可轉換型濾器而言,濾器轉換后將失去攔截血栓的功能,因此在轉換前應嚴格評估發生PE的風險;濾器植入后發生PE的治療,處理同原發性PE一致,但需要同期處理IVC阻塞或濾器內血栓。

5.7其他并發癥? 可轉換濾型濾器置入或轉換穿刺時,可發生穿刺點出血、血腫、IVC靜脈壁損傷、動靜脈瘺形成等;當行濾器轉換時,可能會由于操作的原因出現鎖定裝置脫落,掉入腔靜脈,最終導致肺栓塞,但患者一般無特殊癥狀。為避免這些并發癥導致嚴重后果,操作時須規范、謹慎,一旦發現,立即處理。

6總結

CF作為非永久型腔靜脈濾器的一種,可有效預防肺動脈栓塞,且安全性高,總體并發癥發生率較低。因CF轉換時間可根據臨床需要延長,理論上不受置時間限制,因此在肺栓塞風險期不確定的DVT患者中應用更具優勢。盡管如此,目前對于CF的前瞻性的、隨訪時間長的高質量研究仍不多。現階段的研究隨訪時間較短,因此需要更多的臨床研究針對性地評估CF整體有效性和安全性。另外,建立一個的適應證規范和一個嚴格的隨訪系統,有利于提高濾器轉換率。

參考文獻:

[1]Wadhera RK,Piazza G.Treatment Options in Massive and Submassive Pulmonary Embolism[J].Cardiology in Review,2016,24(1):19-25.

[2]Huang W,Goldberg RJ,Anderson FA,et al.Secular Trends in Occurrence of Acute Venous Thromboembolism:The Worcester VTE Study(1985-2009)[J].The American Journal of Medicine,2014,127(9):829-839.

[3]Park B,Messina L,Dargon P,et al.Recent trends in clinical outcomes and resource utilization for pulmonary embolism in the United States:findings from the nationwide inpatient sample[J].Chest,2009,136(4):983-990.

[4]Law Y,Chan YC,Cheng SWK.Epidemiological updates of venous thromboembolism in a Chinese population[J].Asian Journal of Surgery,2018,41(2):176-182.

[5]Almestady R,Spain J,Bayona-Molano Mdel P,et al.Iatrogenic migration of VenaTech LP IVC filter to superior vena cava secondary to guidewire entrapment:case report and review of literature[J].Vasc Endovascular Surg,2013,47(1):48-50.

[6]Kuy SR,Dua A,Lee CJ,et al.National Trends in Utilization of IVC Filters over a Decade in the United States,2000-2009[J].Journal of Vascular Surgery,2013,57(5):73S-74S.

[7]Wadhwa V,Trivedi PS,Chatterjee K,et al.Decreasing Utilization of Inferior Vena Cava Filters in Post-FDA Warning Era:Insights From 2005 to 2014 Nationwide Inpatient Sample[J].Journal of the American College of Radiology,2017,14(9):1144-1150.

[8]Hohenwalter EJ,Stone JR,O'Moore PV,et al.Multicenter Trial of the VenaTech Convertible Vena Cava Filter[J].Journal of Vascular and Interventional Radiology,2017,28(10):1353-1362.

[9]李津凱,闞世廉,李俊海,等.可轉換型與可回收型腔靜脈濾器的臨床應用[J].中華普通外科雜志,2016,31(7):569-572.

[10]Narayan A,Hong K,Streiff Ml.et al.The Impact of Cancer on the Clinical Outcome of Patients After Inferior Vena Cava Filter Placement:A Retrospective Cohort Study[J].American Journal of Clinical Oncology,2016,39(3):294-301.

[11]Deso SE,Idakoji IA,Kuo WT.Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type[J].Seminars in Interventional Radiology,2016,33(2):93-100.

[12]張福先,李曉強,劉建龍,等.腔靜脈濾器臨床應用指南[J].中國實用外科雜志,2019,39(7):651-654.

[13]Kaufman JA,Rundback JH,Kee ST,et al.Development of a research agenda for inferior vena cava filters:proceedings from a multidisciplinary research consensus panel[J].Journal of Vascular and Interventional Radiology,2009,20(6):697-707.

[14]Steinberger JD,Genshaft SJ.The Role of Inferior Vena Cava Filters in Pulmonary Embolism[J].Techniques in vascular and interventional radiology,2017,20(3):197-205.

[15]Winokur RS,Bassik N,Madoff DC,et al.Radiologists' Field Guide to Retrievable and Convertible Inferior Vena Cava Filters[J].American Journal of Roentgenology,2019,213(4):768-777.

[16]鄒君杰,楊宏宇,章希煒,等.腔靜脈直徑與臨時濾器植入后靜脈內膜增生的相關性分析[J].中華普通外科雜志,2011,26(12):1046-1047.

[17]Le Blanche AF,Ricco JB,Bonneau M,et al.The optional VenaTech(TM) Convertible(TM)vena cava filter:experimental study in sheep[J].Cardiovascular and Interventional Radiology,2012,35(5):1181-1187.

[18]Ayad MT,Gillespie DL.Long-term complications of inferior vena cava filters[J].Journal of Vascular Surgery:Venous and Lymphatic Disorders,2017,5(1):33-41.

[19]Renno A,Khateeb F,Kazan V,et al.A single center experience with retrievable IVC filters[J].Vascular,2015,23(4):350-357.

[20]Alkhouli M,Morad M,Narins CR,et al.Inferior Vena Cava Thrombosis[J].JACC Cardiovascular Interventions,2016,9(7):629-643.

[21]Klinken S,Humphries C,Ferguson J.Establishment of an inferior vena cava filter database and interventional radiology led follow-up-retrieval rates and patients lost to follow-up[J].Journal of medical imaging and radiation oncology,2017,61(5):630-635.

[22]Siracuse JJ,Al Bazroon A,Gill HL,et al.Risk factors of nonretrieval of retrievable inferior vena cava filters[J].Annals of Vascular Surgery,2015,29(2):318-321.

[23]Casanegra AI,Landrum LM,Tafur AJ.Retrievable Inferior Vena Cava Filters in Patients with Cancer:Complications and Retrieval Success Rate[J].International Journal of Vascular Medicine,2016(2016):1-8.

[24]Mikhael B,Albaghdadi M,Abtahian F,et al.Usefulness of a Computerized Reminder System to Improve Inferior Vena Cava Filter Retrieval and Complications[J].The American Journal of Cardiology,2019,123(2):348-353.

[25]Mohapatra A,Liang NL,Chaer RA,et al.Persistently low inferior vena cava filter retrieval rates in a population-based cohort[J].J Vasc Surg Venous Lymphat Disord,2019,7(1):38-44.

[26]Vena Caval Filter Consensus Conference.Recommended reporting standards for vena caval filter placement and patient follow-up[J].J Vasc Interv Radiol,2003,14(9 Pt 2):S427-S432.

[27]Millward SF,Grassi CJ,Kinney TB,et al.Reporting Standards for Inferior Vena Caval Filter Placement and Patient Follow-up:Supplement for Temporary and Retrievable/Optional Filters[J].Journal of Vascular and Interventional Radiology,2009,20(7):S374-S376.

[28]Ferral H.Device Failure during Deployment of VenaTech Convertible Filter Resulting in Filter Migration to the Heart[J].Journal of Vascular and Interventional Radiology,2016,27(11):1720-1722.

[29]Almestady R,Spain J,Bayona-Molano Mdel P,et al.Iatrogenic Migration of VenaTech LP IVC Filter to Superior Vena Cava Secondary to Guidewire Entrapment:Case Report and Review of Literature[J].Vascular&Endovascular Surgery,2013,47(1):48-50.

[30]Chen L,Zhang J,Yang Z.Inferior Vena Cava Filter Migration to the Left Internal Iliac Vein[J].Annals of Vascular Surgery,2020(65):289.

[31]Zhang H,Niu L,Zhang F,et al.Complete Laparoscopic Retrieval of Inferior Vena Cava Filter:A Case Report and Literature Review[J].Annals of Vascular Surgery,2019(57):276.

[32]Hudali T,Zayed A,Karnath B,et al.A fractured inferior vena cava filter strut migrating to the left pulmonary artery[J].Respiratory Medicine Case Reports,2015(16):3-6.

[33]Lee JK,So YH,Choi YH,et al.Clinical course and predictive factors for complication of inferior vena cava filters[J].Thrombosis Research,2014,133(4):538-543.

[34]Ishigami N,Nagai T,Arakawa J,et al.Successful Endovascular Removal of a Perforated Inferior Vena Cava Filter Complicated by a Large Retroperitoneal Hematoma:Pitfall of Catheter-Directed Thrombolysis[J].International Journal of Angiology,2016,25(1):70-74.

[35]Manzur M,Ochoa C,Ham SW,et al.Surgical Management of Perforated Inferior Vena Cava Filters[J].Annals of Vascular Surgery,2017(42):25-31.

[36]Teter K,Schrem E,Ranganath N,et al.Presentation and Management of Inferior Vena Cava Thrombosis[J].Annals of Vascular Surgery,2019(56):17-23.

收稿日期:2020-03-02;修回日期:2020-04-14

編輯/杜帆

猜你喜歡
并發癥
直腸癌Miles術后造口旁疝護理新進展
今日健康(2016年12期)2016-11-17 13:30:12
老年臥床病人并發癥的預防及護理
今日健康(2016年12期)2016-11-17 13:13:23
雙J管在上尿路結石手術應用中的常見并發癥及療效
今日健康(2016年12期)2016-11-17 12:59:44
帶膜支架聯合化療治療晚期食管癌的臨床觀察
改良Devine 術與傳統Shiraki 治療小兒隱匿性陰莖的臨床探討
無張力疝氣修補術與傳統疝氣修補術治療腹股溝疝的療效對比
淺析美軍戰斗精神的致命并發癥
人間(2016年27期)2016-11-11 17:32:04
VSD護理新進展探討
人人健康(2016年21期)2016-11-05 11:32:22
肥胖的流行病學現狀及相關并發癥的綜述
科技視界(2016年18期)2016-11-03 21:58:33
腹腔鏡膽囊切除術后舒適護理模式對疼痛感的控制效果
主站蜘蛛池模板: 亚洲天堂久久| 免费黄色国产视频| 日韩精品毛片| 亚洲色图另类| 夜夜拍夜夜爽| 伊人网址在线| 国产浮力第一页永久地址| 熟女成人国产精品视频| 色视频久久| 国产午夜无码专区喷水| 国产99在线观看| 国产男女免费完整版视频| 美女被操91视频| 亚洲av片在线免费观看| 污网站免费在线观看| 凹凸国产分类在线观看| 色有码无码视频| 亚洲国产中文综合专区在| 天堂亚洲网| 久久久久久高潮白浆| 国产欧美精品一区aⅴ影院| 亚洲日本www| 国内自拍久第一页| 亚洲人成网线在线播放va| 毛片网站在线播放| yy6080理论大片一级久久| 亚洲人妖在线| 国产精品亚洲αv天堂无码| 精品欧美视频| 日韩无码黄色| 国产91视频观看| 久久一色本道亚洲| 国产91精品调教在线播放| 国产91av在线| 无码'专区第一页| 国产一区在线观看无码| 精品久久香蕉国产线看观看gif | 福利一区三区| 免费人成网站在线观看欧美| 欧美成人午夜在线全部免费| 久久免费精品琪琪| 91外围女在线观看| 国产一区二区精品福利| 国产精品xxx| 欧美日韩亚洲国产主播第一区| 国产无码精品在线播放| 激情无码字幕综合| 高h视频在线| 9啪在线视频| 亚洲国产系列| 激情综合图区| 国产va欧美va在线观看| www.99在线观看| 国产福利拍拍拍| 日韩免费中文字幕| 久久99国产精品成人欧美| 国产成人免费高清AⅤ| 国产激情第一页| 四虎亚洲国产成人久久精品| 国产成人精品一区二区秒拍1o | 成人国产精品网站在线看| 丰满人妻中出白浆| 久久久黄色片| 久久天天躁狠狠躁夜夜躁| 欧美亚洲一区二区三区导航| 欧美视频在线播放观看免费福利资源| 亚洲人成网站色7799在线播放| 国产成人在线无码免费视频| 欧美一道本| 青青草原国产精品啪啪视频| 五月丁香在线视频| 国产久操视频| 青青草国产在线视频| 波多野结衣无码AV在线| 国产精品福利导航| 91精品国产麻豆国产自产在线| 亚洲成综合人影院在院播放| 欧美色综合久久| 在线观看国产小视频| 九色免费视频| 制服丝袜亚洲| 亚洲人成网站18禁动漫无码|