999精品在线视频,手机成人午夜在线视频,久久不卡国产精品无码,中日无码在线观看,成人av手机在线观看,日韩精品亚洲一区中文字幕,亚洲av无码人妻,四虎国产在线观看 ?

RPIP—HPLC—ICP—MS測定飲用水中鉻形態

2018-02-03 16:11:01祝銀劉琴楊承虎王范盛李子孟宋凱
現代農業科技 2018年1期
關鍵詞:高效液相色譜

祝銀+劉琴+楊承虎+王范盛+李子孟+宋凱

摘要 本文建立一種改進的高效液相色譜-電感耦合等離子體質譜法測定淡水中鉻形態的方法。通過樣品加標回收驗證本方法的準確度,本方法Cr(Ⅲ)和Cr(Ⅵ)的回收率均在93%~115%之間。通過制備7個濃度水平確定得到鉻元素的校準曲線范圍,Cr(Ⅲ)和Cr(Ⅵ)的相關系數接近1(r=0.999 9),Cr(Ⅲ)和Cr(Ⅵ)的LOD分別為0.094、0.100 μg/L,Cr(Ⅲ)的LOQ為0.28 μg/L,Cr(Ⅵ)為0.30 μg/L。綜上所述,方法的定量限、重現性和準確度滿足淡水中Cr(Ⅲ)和Cr(Ⅵ)的定量分析,可以有效應用于其預期的使用。

關鍵詞 形態分析;鉻形態;飲用水;高效液相色譜-電感耦合等離子體質譜法

中圖分類號 O657.7+2;O657.63 文獻標識碼 A 文章編號 1007-5739(2018)01-0174-02

Determination of Chromium Speciation in Drinking Water by RPIP-HPLC-ICP-MS

ZHU Yin 1,2 LIU Qin 1,2 YANG Cheng-hu 1,2 WANG Fan-sheng 1,2 LI Zi-meng 1,2 SONG Kai 1,2

(1 Marine Fisheries Research Institute of Zhejiang Province,Zhoushan Zhejiang 316021; 2 Key Lab of Sustainable Utilization of Technology Research for Fishery Resource of Zhejiang Province)

Abstract The approach presented in this paper refered to the modification of a method for the detection and quantitative determination of chromium species in water by high-performance liquid chromatography inductively coupled plasma mass spectrometry. The accuracy of the method was verified by sample adding recovery estimation. The recovery rates of both determined analytes were between 93% and 115%.Calibration curve was obtained by preparing seven concentration levels of each chromium species. In both cases,the correlation coefficient was close to 1(r=0.999 9)for Cr(Ⅲ)and Cr(Ⅵ). Using the HPLC-ICP-MS method,LOD was 0.094 μg/L and 0.100 μg/L for Cr(Ⅲ)and Cr(Ⅵ),respectively. According to the modified blank determination method,LOQ for Cr(Ⅲ)was 0.28 μg/L and for Cr(Ⅵ)was 0.30 μg/L.As a result of the method validation experiment,the obtained limit of quantification,repeatability and intermediate precision were satisfied for the quantification of Cr(Ⅲ)and Cr(Ⅵ)in water matrices. The method can be applied effectively for its intended use.

Key words speciation analysis;chromium speciation;drinking water;HPLC-ICP-MS

鉻是硬度最大的金屬元素,化學符號Cr,廣泛分布于環境中,并且在工業中有許多應用,例如電鍍與鋼鐵業[1]。在鉻的幾種存在形式中,Cr(Ⅲ)是人體必需的營養物質,但Cr(Ⅵ)是劇毒,具強氧化性,并且極易滲透生物膜[2]。目前,歐盟飲用水中允許的總鉻含量是50 μg/L。國內現行地表水的Cr(Ⅵ)根據不同的水域對應不同限量值,Ⅴ類水質限量為100 μg/L,Ⅱ類、Ⅲ類和Ⅳ類水質限量均為50 μg/L,Ⅰ類限量為10 μg/L。

高效液相色譜-電感耦合等離子體質譜技術(HPLC-ICP-MS)是測定水樣中鉻元素形態的良好分析手段。ICP-MS作為最靈敏的檢測器之一,具有元素特異性、寬線性動態范圍和極低檢測限等優點[3]。ICP-MS的動態反應池技術(DRC)極大地降低了40Ar12C+和35Cl16OH+的光譜干擾,從而提高了鉻元素分析的靈敏度[4]。鉻形態分析的色譜方法可能包括離子色譜(IC),離子對反相色譜(RPIPC)。RPIP-HPLC是廣泛使用的一種簡單、靈活、靈敏的分離鉻化合物的方法。盡管在這一領域擁有大量文獻,但尚未建立充分有效的方法,尤其是關于形態分析的可追溯性和不確定度測量的論證。本研究的目的是使用RPIP-HPLC-ICP-MS測定飲用水中Cr(Ⅲ)和Cr(Ⅵ),并對分析程序進行詳細的驗證。

1 材料與方法

1.1 儀器設備

ICP-MS:7900a型(USA,Agilent);HPLC:1220型(USA,Agilent)。色譜柱:Perkin Elmer C8(3.3 mm,3 μm);柱溫25 ℃;進樣體積50 μL;流速1.2 mL/min;流動相0.8 mmol/L TBAH,0.6 mmol/L EDTA,pH=6.9;洗脫程序為等度洗脫;總進樣時間3 min。質譜條件RF 功率1 050 W;采樣深度7.8 mm;冷卻氣流量(Ar)13 L/min;等離子體氣流量(Ar)15 L/min;霧化氣流量(Ar)0.88 L/min;輔助氣流量(Ar)1.2 L/min;樣品提升速率0.8 mL/min;采集時間750 s;積分時間1 s;監測質量數(m/z+)為52Cr+;采樣錐和截取錐為Ni。

1.2 試劑材料

Cr(Ⅵ)標準儲備溶液1 000 mg/L,NSI;Cr(Ⅲ)標準儲備溶液1 000 mg/L,NSI;四丁基氫氧化銨(TBAH,美國Sigma-Aldrich 公司);乙二胺四乙酸(EDTA),分析純;硝酸,優級純;甲醇,優級純。

1.3 樣品處理

樣品收集在100 mL聚乙烯瓶中,并立即凍結,在分析前除霜。樣品經0.2 μm再生纖維素濾膜過濾。樣品與流動相按體積比3∶1稀釋,保存在玻璃瓶中,室溫下1 h左右,形成(CrEDTA)-復合物。

2 結果與分析

2.1 線性范圍

用10 μg/L的標準溶液配置工作曲線(n=7),確定Cr(Ⅲ)和Cr(Ⅵ)的保留時間。通過分析極端濃度分析物的方差,確定工作曲線范圍,并根據文獻計算F值[5]。在本研究中,F值估計鉻元素校準曲線的濃度限值為0.3、10.0 μg/L??梢缘贸鼋Y論,計算結果的方差在統計學上無顯著差異。因此,校準曲線的選擇是正確的。制備7個濃度水平(0.3、1.0、2.0、3.0、5.0、7.5、10.0 μg/L)的點分別得到鉻元素的校準曲線,Cr(Ⅲ)和Cr(Ⅵ)的相關系數接近1(r=0.999 9)。Cr(Ⅵ)的靈敏度高于Cr(Ⅲ)。

2.2 檢出限和定量限

檢出限(LOD)定義為可以可靠測量的最低濃度。這個值是由空白樣品-空白測定方法信號的標準偏差的3倍計算出來的[6-8]。在本研究中,使用了以下3種方法測定LOD:①改進的空白測定方法?;趯啥糠治龅目瞻讟颖镜臏y定:LOD=3 S。其中S表示鉻元素濃度為的0.5 μg/L時10個獨立測量值的標準偏差(n=3)[5,9]。②圖解法?;?個標準溶液的標準偏差得到,根據公式LOD=3 S0(S0表示截距)計算Cr(Ⅲ)和Cr(VI)(n=6)濃度為0.3、0.4、0.5 μg/L時的標準偏差。③線性回歸方法?;谛盘柕臉藴势詈托是€的斜率(標準偏差/斜率比)計算:LOD=3.3 S/b。其中,S表示表示信號的標準偏差(根據校準曲線估計),b為校準曲線的斜率[5,10]。定量限(LOQ)是分析物定量測定的最低濃度,可用精度和準確度的可接受水平確定。在本研究中,計算為3倍LOD。采用HPLC-ICP-MS法,根據改進的空白測定方法Cr(Ⅲ)和Cr(Ⅵ)的LOD分別為0.094、0.100 μg/L[Cr(Ⅲ)的LOQ為0.28 μg/L,Cr(Ⅵ)為0.30 μg/L]。因為在m/z+為52時,鉻元素的LOD值為背景標準偏差的3倍(表1)。因此,得到的結果易于與其他比較。

2.3 精密度

精密度在重現性和中間精密度條件下確定,并通過分析加入了2 μg/L鉻元素標準溶液的飲用水進行評估。重現性和中間精密度表示為變異系數(CV)。同一操作者在短時間內使用相同的方法和設備測定重現性,在同一天重復測量上述水樣10次。對于Cr(Ⅲ)和Cr(Ⅵ),得到的結果分別為1.5%和1.6%。所得結果對應于先前提出的值。

同一操作者在較長時間內用相同方法獲得的結果評估中間精密度,連續3 d從相同的加標飲用水樣品中進行測定。得到變異系數Cr(Ⅲ)為3.4%、Cr(Ⅵ)為3.5%,表明中間精密度良好。

2.4 準確度

評價方法準確度最常用的方式是使用特定標準物質。本研究中,因為缺少適用于鉻形態分析的標準物質[13,18-19],方法通過確定每個分析物的回收率來驗證優化分析過程的效率。將2種鉻元素添加到濃度為2.0 μg/L的4種不同水體基質中,在飲用水加標溶液中進行的回收率結果見表2??梢钥闯?,提出的方法可以檢測水中存在的Cr(Ⅲ)和Cr(Ⅵ),并且低于WHO提出的水中總鉻含量。采集的樣品中檢測出鉻元素的回收率在93%~115%之間。結果表明,Cr(Ⅲ)和Cr(Ⅵ)的回收率在±10%之內。加標樣品回收率在加標值±25%以內,則認為可接受。該標準由美國EPA方法6020A推薦用于ICP-MS的元素分析,并在本研究中得到確認。

3 結論

目前,鉻的形態分析主要是在環境樣品中進行。HPLC-ICP-MS法使飲用水中Cr(Ⅲ)和Cr(Ⅵ)的檢測和量化快速、準確。采用改良的空白測定法測定LOD,并將所得結果與其他研究人員所得的值進行比較。在大部分鉻形態研究文獻中,LOD通常用最簡單的方法計算,即背景的3倍標準偏差。每個元素的回歸系數為0.999 9,從而證明了該方法的線性和重現性。對加標樣品的定量分析表明,2種鉻元素的回收率在93%~115%之間。

4 參考文獻

[1] KOTAS′ J,STASICKA Z.Chromium occurrence in the environment and methods of its speciation[J].Environ Pollut,2000(107):263-283.

[2] METZE D,JAKUBOWSKI N,KLOCKOW D.Speciation of chromium[M]//CORNELIS R,CREWS H,CARUSO J,et al.Handbook of elemental spe-ciation II:Species in the environment,food,medicine and occupational health. New York:Wiley,2005.

[3] WROBEL K,CARUSO JA.Elemental and isotope ratio mass spectrometry [M]//GROSS M L,CAPRIOLI R M.The encyclopedia of mass spectrometry,Volume 5:elemental and isotope ratio mass spectrometry.Oxford:Elsevier,2010.

[4] EIDEN G,BARINAGA C J,KOPPENAAL D W[M]//GROSS ML,CAPRI-OLI RM.The encyclopedia of mass spectrometry,Volume 5:elemental and isotope ratio mass spectrometry. Oxford:Elsevier,2010.

[5] KONIECZKA P,NAMIES′NIK J.Quality assurance and quality control in the analytical chemical laboratory[M]//A practical approach. Boca Raton:Taylor & Francis Group,2009.

[6] KUO CY,JIANG SJ,SAHAYAM AC.Speciation of chromium and vanad-ium in environmental samples using HPLC-DRC-ICP-MS[J].J Anal At Spectrom,2007(22):636-641.

[7] CHANG Y L,JIANG S J.Determination of chromium species in water samples by liquid chromatography-inductively coupled plasma-dynamic reaction cell-mass spectrometry[J].J Anal At Spectrom,2001(16):858-862.

[8] NEUBAUER K,REUTER W,PERRONE P.Chromium speciation in water by HPLC/ICP-MS:Application Note[Z].Norwalk:Perkin Elmer,2003.

[9] EURACHEM GUIDE.The fitness for purpose of analytical methods:a laboratory guide to method validation and related topics[Z].Teddington:LGC,1998.

[10] GU¨RLEYU¨KH,WALLSCHLA¨GERD.Determination of chromium(III)and chromium(VI)using suppressed ion chromatography inductively coupled plasma mass spectrometry[J].J Anal At Spectrom,2001(16):926-930.

[11] XING L,BEAUCHEMIN D.Chromium speciation at trace level in potable water using hyphenated ion exchange chromatography and inductively coupled plasma mass spectrometry with collision/reaction interface[J].J Anal At Spectrom,2010(25):1046-1055.

[12] International Conference on Harmonisation of Technical Requirements for Registration of Pharmaceuticals for Human Use. ICH Guideline Q2(R1):validation of analytical procedures:text and methodology[EB/OL].[2013-02-12].http://www.ich.org/.

[13] CHEN Z L,MEGHARAJ M,NAIDU R.Removal of interferences in the speciation of chromium using an octopole reaction system in ion chromatography with inductively coupled plasma mass spectrometry[J].Talanta,2007(73):948-952.

[14] WOLF R E,MORRISON J M,GOLDHABER M B.Simultaneous determi-nation of Cr(III)and Cr(VI)using reversed-phased ionpairing liquid chromatography with dynamic reaction cell inductively coupled plasma mass spectrometry[J].J Anal At Spectrom,2007(22):1051-1060.

[15] WANG HJ,DU XM,WANG M,et al.Using ion-pair reversed-phase HPLC ICP-MS to simultaneously determine Cr(III)and Cr(VI)in urine of chromate workers[J].Talanta,2010(81):1856-1860.

[16] VANHAECKE F,SAVERWYNS S,DE WANNEMACKER G,et al.Comparison of the application of higher mass resolution and cool plasma conditions to avoid spectral interferences in Cr(III)/Cr(VI)speciation by means of high-performance liquid chromatography-inductively coupled plasma mass spectrometry[J].Anal Chim Acta,2000(419):55-64.

[17] SE′BY F,CHARLES S,GAGEAN M,et al.Chromium speciation by hy-phenation of high-performance liquid chromatography to inductively coupled plasma-massspectrometry:study of the influence of interfering ions[J].J Anal At Spectrom,2003(18):1386-1390.

[18] XIE Q,KERRICH R,IRVING E,et al.Determination of five arsenic sp-ecies in aqueous samples by HPLC coupled with a hexapole collision cell ICP-MS[J].J Anal At Spectrom,2002(17):1037-1041.

[19] CASTILLO A,ROIG-NAVARRO A F,POZO O J.Capabilities of microbore columns coupled to inductively coupled plasma mass spectrometry in speciation of arsenic and selenium[J].J Chromatogr A,2008(1202):132-137.

猜你喜歡
高效液相色譜
QuEChERS—高效液相色譜—串聯質譜法測定植物源食品中環磺酮殘留
分析化學(2017年1期)2017-02-06 21:32:17
薄層色譜和高效液相色譜用于矮地茶多糖的單糖組成分析
高效液相色譜—串聯質譜法測定檳榔中9種有機磷農藥殘留
高效液相色譜—二極管陣列檢測器法測定膠囊殼中20種禁用工業染料
分析化學(2016年7期)2016-12-08 00:57:07
HPLC-MS-MS法測定克拉霉素血藥濃度的含量
上海醫藥(2016年21期)2016-11-21 23:14:07
高效液相色譜技術在石油化工中的應用分析
高效液相色譜概述及其在藥品檢驗中的應用
高效液相色譜法測定大豆異黃酮片中的大豆異黃酮的含量
腦蛋白水解物片劑肽含量測定方法的改進
上海醫藥(2016年3期)2016-03-23 23:38:20
HPLC和TLC法對藍色簽字筆墨水分類鑒定研究
主站蜘蛛池模板: 日韩一二三区视频精品| 国产一级毛片在线| 国产第二十一页| 亚洲人成色77777在线观看| 最新国产午夜精品视频成人| 免费久久一级欧美特大黄| 日本一本在线视频| 91国内在线观看| 999精品视频在线| 久久久久免费看成人影片| 欧美日韩中文国产| av大片在线无码免费| 成人av手机在线观看| 丝袜高跟美脚国产1区| 日韩精品无码不卡无码| 毛片在线区| 国产丝袜无码一区二区视频| 色爽网免费视频| 亚洲天堂网2014| www.91在线播放| 9久久伊人精品综合| 伊人色在线视频| 亚洲aaa视频| 激情無極限的亚洲一区免费| 天天摸天天操免费播放小视频| 99无码熟妇丰满人妻啪啪| 国产丝袜91| 国产一二三区视频| 毛片网站免费在线观看| 国产精品一区不卡| 91精品啪在线观看国产60岁| 91久久偷偷做嫩草影院电| 99人体免费视频| a级毛片在线免费观看| 青青草欧美| 青草国产在线视频| 国产免费怡红院视频| 国产精品一老牛影视频| 中文字幕在线欧美| 91年精品国产福利线观看久久 | 手机在线国产精品| 亚洲国产日韩一区| 国产91小视频| 久久这里只有精品66| 午夜国产精品视频| 国产精品分类视频分类一区| 久久这里只有精品免费| 一级在线毛片| 国产精品天干天干在线观看| 麻豆AV网站免费进入| 国产精品久久久久久久久久98| h视频在线观看网站| 日韩大片免费观看视频播放| 亚洲AV成人一区二区三区AV| 国产乱人乱偷精品视频a人人澡| 播五月综合| www.国产福利| 67194亚洲无码| 福利国产微拍广场一区视频在线| 青青国产视频| 2048国产精品原创综合在线| 国产一二三区视频| 亚洲成年人片| 伊人久久精品亚洲午夜| 久久毛片基地| 精品自窥自偷在线看| 成人免费午夜视频| 国产成人福利在线视老湿机| 久久精品国产免费观看频道| 激情亚洲天堂| 国产精品视频猛进猛出| 国产无码性爱一区二区三区| 久久狠狠色噜噜狠狠狠狠97视色 | 天天躁狠狠躁| 国产欧美自拍视频| 国产特级毛片aaaaaaa高清| 国产成人1024精品下载| 中文字幕日韩欧美| 九九这里只有精品视频| 狠狠色狠狠综合久久| 福利在线不卡| 中文字幕乱码二三区免费|